Fiber-optic fluorescence correlation spectrometer

被引:19
作者
Garai, Kanchan [1 ]
Muralidhar, Mohan [1 ]
Maiti, Sudipta [1 ]
机构
[1] Tata Inst Fundamental Res, Bombay 400005, Maharashtra, India
关键词
D O I
10.1364/AO.45.007538
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fluorescence correlation spectroscopy (FCS) is a sensitive technique used to probe size, concentration, flow velocity, and reaction kinetics in a dilute solution. Conventional FCS spectrometers achieve this sensitivity at the cost of using bulky optics. We demonstrate a technique that utilizes a single-mode optical fiber of 3.3 mu m mode field diameter to perform FCS measurements. We demonstrate that the technique has adequate sensitivity to perform FCS measurements on fluorescent beads of 13 nm radius, and that the results agree with theoretical predictions. Our method potentially allows FCS to be extended to remote and in vivo applications. (c) 2006 Optical Society of America.
引用
收藏
页码:7538 / 7542
页数:5
相关论文
共 21 条
[1]   Axial resolution limit of a fiber-optic fluorescence probe [J].
Balaji, J ;
Garai, K ;
Chakrabarti, S ;
Maiti, S .
APPLIED OPTICS, 2003, 42 (19) :3780-3784
[2]   Semiconductor nanocrystals as fluorescent biological labels [J].
Bruchez, M ;
Moronne, M ;
Gin, P ;
Weiss, S ;
Alivisatos, AP .
SCIENCE, 1998, 281 (5385) :2013-2016
[3]   Quantum dot bioconjugates for ultrasensitive nonisotopic detection [J].
Chan, WCW ;
Nie, SM .
SCIENCE, 1998, 281 (5385) :2016-2018
[4]   Fluorescence resonance energy transfer between quantum dot donors and dye-labeled protein acceptors [J].
Clapp, AR ;
Medintz, IL ;
Mauro, JM ;
Fisher, BR ;
Bawendi, MG ;
Mattoussi, H .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (01) :301-310
[5]   In vivo molecular and cellular imaging with quantum dots [J].
Gao, XH ;
Yang, LL ;
Petros, JA ;
Marshal, FF ;
Simons, JW ;
Nie, SM .
CURRENT OPINION IN BIOTECHNOLOGY, 2005, 16 (01) :63-72
[6]   On the validity of blood flow measurement using colored microspheres [J].
Hodeige, D ;
De Pauw, M ;
Eechaute, W ;
Weyne, J ;
Heyndrickx, GR .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 276 (04) :H1150-H1158
[7]   Fluctuations and stimulus-induced changes in blood flow observed in individual capillaries in layers 2 through 4 of rat neocortex [J].
Kleinfeld, D ;
Mitra, PP ;
Helmchen, F ;
Denk, W .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (26) :15741-15746
[8]   STATISTICAL ACCURACY IN FLUORESCENCE CORRELATION SPECTROSCOPY [J].
KOPPEL, DE .
PHYSICAL REVIEW A, 1974, 10 (06) :1938-1945
[9]   Simple optical fibre biosensor based on immobilised enzyme for monitoring of trace heavy metal ions [J].
Kuswandi, B .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (07) :1104-1110
[10]   THERMODYNAMIC FLUCTUATIONS IN A REACTING SYSTEM - MEASUREMENT BY FLUORESCENCE CORRELATION SPECTROSCOPY [J].
MAGDE, D ;
WEBB, WW ;
ELSON, E .
PHYSICAL REVIEW LETTERS, 1972, 29 (11) :705-&