Augmentation of femoral neck fracture fixation with an injectable calcium-phosphate bone mineral cement

被引:79
作者
Stankewich, CJ [1 ]
Swiontkowski, MF [1 ]
Tencer, AF [1 ]
Yetkinler, DN [1 ]
Poser, RD [1 ]
机构
[1] NORIAN CORP, CUPERTINO, CA USA
关键词
D O I
10.1002/jor.1100140516
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The first goal of this study was to determine if augmentation with an injectable, in situ setting, calcium-phosphate cement that is capable of being remodeled and was designed to mimic home mineral significantly improved the strength and stiffness of fixation in a cadaveric femoral neck fracture model. The second goal was to determine if greater increases in fixation strength were achieved as the bone density of the specimen decreased. Sixteen pairs of fresh cadaveric human femora with a mean age of 70.9 years (SD = 17.2 years) were utilized. The bone density of the femoral neck was measured with dual-energy x-ray absorptiometry. The femoral head was impacted vertically with the femoral shaft fixed in 12 degrees of adduction using a materials testing machine to create a fully displaced fracture. Following fracture, 30% inferior comminution was created in each specimen. One randomly chosen femur from each pair underwent anatomic reduction and fixation with three cannulated cancellous bone screws, 7 mm in diameter, in an inverted triangle configuration. The contralateral femur underwent the same fixation augmented with calcium-phosphate cement. Specimens were preconditioned followed by 1,000 cycles to one body weight (611.6 N) at 0.5 Hz to simulate single-limb stance loading. The stiffness in the first cycle was observed to be significantly greater in cement-augmented specimens compared with unaugmented controls (p < 0.05). After cycling, each specimen was loaded at 10 mm/min until complete displacement of the fracture surface and failure of fixation occurred. Specimens augmented with bone mineral cement failed at a mean of 4,573 N (SD = 1,243 N); this was significantly greater (p < 0.01) than the mean for controls (3,092 N, SD = 1,258 N). The relative improvement in fixation strength (augmented/control x 100%) was not inversely correlated to femoral neck bone density (p = 0.25, R(2) = 0.09), was weakly correlated to the volume of cement injected (p = 0.001, R(2) = 0.54). There was a mean relative improvement in fixation strength of 169.6% (SD = 77.5). These findings suggest that calcium-phosphate cement provides initial beneficial augmentation to fixation of femoral neck fractures.
引用
收藏
页码:786 / 793
页数:8
相关论文
共 27 条
  • [1] ALHO A, 1988, CLIN ORTHOP RELAT R, P292
  • [2] THE EFFECT OF ADJUNCTIVE METHYLMETHACRYLATE ON FAILURES OF FIXATION AND FUNCTION IN PATIENTS WITH INTERTROCHANTERIC FRACTURES AND OSTEOPOROSIS
    BARTUCCI, EJ
    GONZALEZ, MH
    COOPERMAN, DR
    FREEDBERG, HI
    BARMADA, R
    LAROS, GS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) : 1094 - 1107
  • [3] CHAPMAN JR, 1996, ASME, V118, P391, DOI DOI 10.1115/1.2796022
  • [4] SKELETAL REPAIR BY IN-SITU FORMATION OF THE MINERAL PHASE OF BONE
    CONSTANTZ, BR
    ISON, IC
    FULMER, MT
    POSER, RD
    SMITH, ST
    VANWAGONER, M
    ROSS, J
    GOLDSTEIN, SA
    JUPITER, JB
    ROSENTHAL, DI
    [J]. SCIENCE, 1995, 267 (5205) : 1796 - 1799
  • [5] ELDER S, UNPUB BIOMECHANICAL
  • [6] FRANKENBURG EP, 1994, T ORTHOP RES SOC, V19, P157
  • [7] FRANKENBURG FP, 1996, T ORTHOP RES SOC, V21, P224
  • [8] BIOMECHANICAL OPTIMIZATION OF A MODEL PARTICULATE COMPOSITE FOR ORTHOPEDIC APPLICATIONS
    GERHART, TN
    HAYES, WC
    STERN, SH
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1986, 4 (01) : 76 - 85
  • [9] METHYLMETHACRYLATE AS AN ADJUNCT IN INTERNAL-FIXATION OF PATHOLOGICAL FRACTURES - EXPERIENCE WITH 375 CASES
    HARRINGTON, KD
    SIM, FH
    ENIS, JE
    JOHNSTON, JO
    DICK, HM
    GRISTINA, AG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (08) : 1047 - 1055
  • [10] HOLMBERG S, 1987, CLIN ORTHOP RELAT R, P42