Tongue carcinoma: Tumor volume measurement

被引:33
作者
Chong, VFH
Zhou, JY
Khoo, JBK
Huang, J
Lim, TK
机构
[1] Singapore Gen Hosp, Dept Diagnost Radiol, Singapore 169608, Singapore
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 2263, Singapore
[3] Natl Canc Ctr, Dept Diagnost Imaging, Singapore, Singapore
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2004年 / 59卷 / 01期
基金
英国医学研究理事会;
关键词
tongue carcinoma; magnetic resonance (MR) volume measurement;
D O I
10.1016/j.ijrobp.2003.09.089
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Purpose: To validate the semiautomated methods of tongue carcinoma tumor volume measurement by comparing the conventional manual trace method with 2 semiautomated computer methods: seed growing and region deformation. Materials and Methods: The study population consisted of 16 patients with histology-proven tongue carcinoma. Two-head-and-neck radiologists independently measured the tumor volume demonstrated on pretreatment T2-weighted magnetic resonance data sets. The tumor volumes were measured using manual tracing and semiautomated seed growing and region deformation algorithm. Data were recorded for analysis of interoperator variance and interobserver reliability at volume and pixel levels. Results: There was no significant difference between the manually traced volume and semiautomated segmentation volumes for both operators. No significant difference was found in interobserver variance among the 3 methods at volume level. However, there was significant difference between manual tracing and semiautomated segmentation methods in interobserver reliability at pixel level. Conclusion: The semiautomated methods could achieve satisfactory segmentation results. They could also reduce interoperator variance and obtain a higher interobserver reliability. This study validates the use of semiautomated volume measurement methods for tongue carcinoma. (C) 2004 Elsevier Inc.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 31 条
[1]
Asakage T, 1998, CANCER, V82, P1443, DOI 10.1002/(SICI)1097-0142(19980415)82:8<1443::AID-CNCR2>3.0.CO
[2]
2-A
[3]
DOSE, VOLUME, AND TUMOR-CONTROL PREDICTIONS IN RADIOTHERAPY [J].
BRENNER, DJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (01) :171-179
[4]
Object boundary location by region and contour deformation [J].
Chan, FHY ;
Lam, FK ;
Poon, PWF ;
Zhu, H ;
Chan, KH .
IEE PROCEEDINGS-VISION IMAGE AND SIGNAL PROCESSING, 1996, 143 (06) :353-360
[5]
Volumetric analysis of tumor extent in nasopharyngeal carcinoma and correlation with treatment outcome [J].
Chua, DTT ;
Sham, JST ;
Kwong, DLW ;
Tai, KS ;
Wu, PM ;
Lo, M ;
Yung, A ;
Choy, D ;
Leong, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (03) :711-719
[6]
Automatic tumor segmentation using knowledge-based techniques [J].
Clark, MC ;
Hall, LO ;
Goldgof, DB ;
Velthuizen, R ;
Murtagh, FR ;
Silbiger, MS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (02) :187-201
[7]
MRI SEGMENTATION - METHODS AND APPLICATIONS [J].
CLARKE, LP ;
VELTHUIZEN, RP ;
CAMACHO, MA ;
HEINE, JJ ;
VAIDYANATHAN, M ;
HALL, LO ;
THATCHER, RW ;
SILBIGER, ML .
MAGNETIC RESONANCE IMAGING, 1995, 13 (03) :343-368
[8]
Conover W. J., 1980, PRACTICAL NONPARAMET
[9]
Automatic segmentation of non-enhancing brain tumors in magnetic resonance images [J].
Fletcher-Heath, LM ;
Hall, LO ;
Goldgof, DB ;
Murtagh, FR .
ARTIFICIAL INTELLIGENCE IN MEDICINE, 2001, 21 (1-3) :43-63
[10]
FUKUKANO H, 1997, HEAD NECK-J SCI SPEC, V19, P205