A high capacity completely closed-cycle 250 mK 3He refrigeration system based on a pulse tube cooler

被引:39
作者
Devlin, MJ [1 ]
Dicker, SR [1 ]
Klein, J [1 ]
Supanich, MP [1 ]
机构
[1] Univ Penn, David Rittenhouse Labs, Philadelphia, PA 19104 USA
关键词
cryogen-free; He-3 adsorption refrigerator; pulse tube cooler;
D O I
10.1016/j.cryogenics.2004.03.001
中图分类号
O414.1 [热力学];
学科分类号
摘要
We present the design of a completely closed-cycle refrigeration system. The system consists Of four stages; the first two, 40.5 and 2.7 K, are provided by a pulse tube cooler, the third and fourth stages by helium adsorption refrigerators. The adsorption refrigerators use He-4 and He-3 with base temperatures of 700 and 250 mK, respectively. Performance tests including some with the cooler rotated from the vertical showed that with a load of 15 muK, a temperature below 286 mK can be maintained for 72 h. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:611 / 616
页数:6
相关论文
共 9 条
[1]  
[Anonymous], 1990, Adv. Cryog. Eng.
[2]  
BENFORD DJ, 2003, SPIE, V4850, P944
[3]   A three-stage helium sorption refrigerator for cooling of infrared detectors to 280 mK [J].
Bhatia, RS ;
Chase, ST ;
Edgington, SF ;
Glenn, J ;
Jones, WC ;
Lange, AE ;
Maffei, B ;
Mainzer, AK ;
Mauskopf, PD ;
Philhour, BJ ;
Rownd, BK .
CRYOGENICS, 2000, 40 (11) :685-691
[4]  
ENGELS ML, 1972, CRYOGENICS, V12, P141
[5]  
FRANK DJ, 1986, ADV CRYO ENG, V31, P933
[6]  
HERBERT GR, 1957, PHYS REV, V106, P391
[7]  
POBELL F, 1937, MATTER METHODS LOW T
[8]  
PRESTAGE RM, P SPIE, V4837, P944
[9]   CHARACTERIZATION OF CHARCOALS FOR HELIUM CRYOPUMPING IN FUSION DEVICES [J].
SEDGLEY, DW ;
TOBIN, AG ;
BATZER, TH ;
CALL, WR .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1987, 5 (04) :2572-2576