Noninvasive blood glucose monitoring

被引:129
作者
Klonoff, DC
机构
[1] Department of Medicine, Univ. of California at San Francisco, San Francisco, CA
[2] Metabolic Research Unit, Univ. of California at San Francisco, San Francisco
关键词
D O I
10.2337/diacare.20.3.433
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The concentration of glucose in the blood may soon be measured noninvasively, without puncturing the finger to obtain a drop of blood. Current prototype devices for this purpose require greater accuracy and miniaturization to be commercially viable. No such device has been approved for marketing by the U.S. Food and Drug Administration. The technology used for noninvasive blood glucose monitoring involves either radiation or fluid extraction. With radiation technology, an energy beam is 1) applied to the body, 2) modified proportionate to the concentration of glucose in the blood, and 3) measured. The blood glucose concentration is then calculated. With fluid extraction technology, a body fluid containing glucose in a concentration proportionate to the blood glucose concentration is extracted and measured. The blood glucose concentration is then calculated The most promising technologies are 1) near-infrared light spectroscopy, 2) far-infrared radiation spectroscopy, 3) radio wave impedance, 4) optical rotation of polarized light, 5) fluid extraction from skin, and 6) interstitial fluid harvesting. Each method has features predictive of commercial viability, as well as technical problems to overcome.
引用
收藏
页码:433 / 437
页数:5
相关论文
共 28 条
[1]  
AMATO I, 1992, SCIENCE, V258, P892
[2]   FOURIER-TRANSFORM INFRARED-SPECTROSCOPY AS A POWERFUL TOOL FOR THE STUDY OF CARBOHYDRATES IN AQUEOUS-SOLUTIONS [J].
BACK, DM ;
MICHALSKA, DF ;
POLAVARAPU, PL .
APPLIED SPECTROSCOPY, 1984, 38 (02) :173-180
[3]   Simultaneous measurements of glucose, glutamine, ammonia, lactate, and glutamate in aqueous solutions by near-infrared spectroscopy [J].
Chung, H ;
Arnold, MA ;
Rhiel, M ;
Murhammer, DW .
APPLIED SPECTROSCOPY, 1996, 50 (02) :270-276
[4]   EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[5]   NONINVASIVE OPTICAL POLARIMETRIC GLUCOSE SENSING USING A TRUE PHASE MEASUREMENT TECHNIQUE [J].
COTE, GL ;
FOX, MD ;
NORTHROP, RB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (07) :752-756
[6]   IN-VIVO MONITORING OF LACTATE AND GLUCOSE WITH MICRODIALYSIS AND ENZYME REACTORS IN INTENSIVE-CARE MEDICINE [J].
DEBOER, J ;
KORF, J ;
PLIJTERGROENDIJK, H .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1994, 17 (03) :163-170
[7]  
GINSBERG BH, 1994, DIABETES CARE, V17, P50
[8]   A NEW SYSTEM FOR INVITRO STUDIES OF IONTOPHORESIS [J].
GLIKFELD, P ;
CULLANDER, C ;
HINZ, RS ;
GUY, RH .
PHARMACEUTICAL RESEARCH, 1988, 5 (07) :443-446
[9]  
Goldstein R. J., 1985, HDB HEAT TRANSFER AP
[10]   THE COMPOSITION AND OPTICAL-ROTARY DISPERSION OF BOVINE AQUEOUS-HUMOR [J].
GOUGH, DA .
DIABETES CARE, 1982, 5 (03) :266-270