A porcine model of massive, totally occlusive, pulmonary embolism

被引:19
作者
Kjaergaard, Benedict [1 ,2 ]
Kristensen, Soren Risom [3 ]
Risom, Mads [2 ,4 ]
Larsson, Anders [2 ,4 ]
机构
[1] Aarhus Univ Hosp, Aalborg Hosp, Cardiovasc Res Ctr, Dept Cardiothorac Surg, DK-9100 Aalborg, Denmark
[2] Aarhus Univ, Inst Clin Med, Aarhus, Denmark
[3] Aarhus Univ Hosp, Aalborg Hosp, Cardiovasc Res Ctr, Dept Clin Biochem, DK-9100 Aalborg, Denmark
[4] Aarhus Univ Hosp, Anaesthesia Res Unit, DK-9100 Aalborg, Denmark
关键词
EXTRACORPOREAL MEMBRANE-OXYGENATION; SURGICAL-TREATMENT; RESUSCITATION; MANAGEMENT; THROMBOEMBOLISM;
D O I
10.1016/j.thromres.2009.01.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A reliable, animal model of massive, totally occlusive, pulmonary embolism (PE) is lacking. Objectives: To design an animal model of totally occlusive PE and to challenge the model by a plasminogen activator. Methods: In eight anaesthetized pigs (similar to 90 kg) a massive preformed autologous thrombus was injected into the caval vein. One animal was autopsied to assess the extent of injected clot, whereas in the other animals extracorporeal life support (ECLS) was initiated and continued for three hours. These animals received 100 mg rt-PA. Blood gases, coagulation tests, creatine kinase (CK), lactate dehydrogenase (LDH), end-tidal CO2, systemic and pulmonary artery blood pressures and flow were registered. Results: All animals went into circulatory arrest within 2 minutes after injection of the thrombus. In the animal where ECLS was not started, autopsy relieved a totally occlusive embolus of the pulmonary artery. The ECLS maintained a systemic blood flow of 6-8 L/min with adequate oxygenation and CO2-removal. However, lactate increased and base-excess became negative. Ddimer increased, fibrinogen decreased, and CK and LDH increased. All seven animals were weaned from ECLS. Despite the rt-PA treatment, the animals had at that time low end tidal CO2/PaCO2 ratio and increased mean pulmonary arterial pressure, suggesting a significant amount of embolic material remaining in the pulmonary artery. Conclusion: This model of massive, totally occlusive, pulmonary embolism mimics well fatal PE seen in the clinic, and has the potential for use in testing of new therapeutic interventions. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:226 / 229
页数:4
相关论文
共 18 条
[1]   The dynamic changes of LDH isoenzyme 3 and D-dimes following pulmonary thromboembolism in canine [J].
Ben, Su-qin ;
Ni, Song-shi ;
Shen, Hua-hao ;
Shi, Yu-xin ;
Huang, Shi-bing ;
Xu, Jian-hui ;
Huang, Jian-fei .
THROMBOSIS RESEARCH, 2007, 120 (04) :575-583
[2]   Efficacy of thrombolytic agents in the treatment of pulmonary embolism [J].
Capstick, T ;
Henry, MT .
EUROPEAN RESPIRATORY JOURNAL, 2005, 26 (05) :864-874
[3]   ACUTE MASSIVE PULMONARY EMBOLISM - SUCCESSFUL SURGICAL TREATMENT USING TEMPORARY CARDIOPULMONARY BYPASS [J].
COOLEY, DA ;
BEALL, AC ;
ALEXANDER, JK .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1961, 177 (05) :283-&
[4]   When pulmonary embolism treatment isn't working [J].
Davidson, B ;
Karmy-Jones, R .
CHEST, 2006, 129 (04) :839-840
[5]  
Digonnet Antoine, 2007, Interact Cardiovasc Thorac Surg, V6, P27
[6]   Thrombolytic therapy for pulmonary embolism [J].
Dong, B. ;
Jirong, Y. ;
Liu, G. ;
Wang, Q. ;
Wu, T. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2006, (02)
[7]   Low-dose tenecteplase during cardiopulmonary resuscitaion due to massive pulmonary embolism: a case report and review of previously reported cases [J].
Hefer, David Vaclav Fred ;
Munir, Aman ;
Khouli, Hassan .
BLOOD COAGULATION & FIBRINOLYSIS, 2007, 18 (07) :691-694
[8]   Successful resuscitation of acute massive pulmonary embolism with extracorporeal membrane oxygenation and open embolectomy [J].
Hsieh, PCH ;
Wang, SS ;
Ko, WJ ;
Han, YY ;
Chu, SH .
ANNALS OF THORACIC SURGERY, 2001, 72 (01) :266-267
[9]   Resuscitation and circulatory support using extracorporeal membrane oxygenation for fulminant pulmonary embolism [J].
Kawahito, K ;
Murata, S ;
Adachi, H ;
Ino, T ;
Fuse, K .
ARTIFICIAL ORGANS, 2000, 24 (06) :427-430
[10]   A mobile system for the treatment of accidental hypothermia with extracorporeal circulation [J].
Kjærgaard, B ;
Tolboll, P ;
Lyduch, S ;
Trautner, S .
PERFUSION-UK, 2001, 16 (06) :453-459