Physics and instrumentation for imaging in-vivo drug distribution

被引:26
作者
Singh, M
Waluch, V
机构
[1] Univ So Calif, Dept Radiol, Los Angeles, CA 90089 USA
[2] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
[3] St Vincent Hosp & Med Ctr, MRI Unit, Los Angeles, CA 90057 USA
[4] Univ So Calif, Pharmacokinet Imaging Program, Los Angeles, CA 90089 USA
关键词
nuclear medicine; gamma camera; SPECT; PET; magnetic resonance imaging; magnetic resonance spectroscopy;
D O I
10.1016/S0169-409X(99)00053-8
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Several imaging methods are currently available to measure drugs noninvasively. Of these, two techniques are today central to such measurements: nuclear imaging and magnetic resonance imaging/spectroscopy (MRI and MRS). While other methods, such as optical techniques, are rapidly gaining in interest they have not yet attained the degree of development that makes them effective in measuring drugs in living systems, except in a small number of examples. The following introduction provides some basic elements of the potential and the limitations of both nuclear imaging and MRI/MRS techniques, methods that will be used in the studies described in the articles in this issue. However, and for those desiring to gain a better understanding of both methods, the reader is advised to consult much more extensive reviews and books describing such methods. A suggested list of books and articles on Nuclear Imaging and MRI/MRS is given. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:7 / 20
页数:14
相关论文
共 26 条
[1]  
ANGER HO, 1964, J NUCL MED, V5, P515
[2]  
BLOEMBERGEN N, 1961, NUCL MAGNETIC RESONA
[3]  
BRUCH MD, 1996, NMR SPECTRSCOPY TECH
[4]   3-DIMENSIONAL RECONSTRUCTION IN NUCLEAR-MEDICINE EMISSION IMAGING [J].
BUDINGER, TF ;
GULLBERG, GT .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (03) :2-20
[5]  
BUDINGER TF, 1980, J NUCL MED, V21, P579
[6]   MicroPET: A high resolution PET scanner for imaging small animals [J].
Cherry, SR ;
Shao, Y ;
Silverman, RW ;
Meadors, K ;
Siegel, S ;
Chatziioannou, A ;
Young, JW ;
Jones, WF ;
Moyers, JC ;
Newport, D ;
Boutefnouchet, A ;
Farquhar, TH ;
Andreaco, M ;
Paulus, MJ ;
Binkley, DM ;
Nutt, R ;
Phelps, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1161-1166
[7]  
Cho Z.-H., 1993, FDN MED IMAGING
[8]   IMPLEMENTATION OF 3-DIMENSIONAL IMAGE-RECONSTRUCTION FOR MULTIRING POSITRON TOMOGRAPHS [J].
DEFRISE, M ;
TOWNSEND, D ;
GEISSBUHLER, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1361-1372
[9]  
DEGRAAF RA, 1998, IN VIVO NMR SPECTROS
[10]   QUANTITATIVE-ANALYSIS OF D2 DOPAMINE RECEPTOR-BINDING IN THE LIVING HUMAN-BRAIN BY PET [J].
FARDE, L ;
HALL, H ;
EHRIN, E ;
SEDVALL, G .
SCIENCE, 1986, 231 (4735) :258-261