Dispersal of exhaled air and personal exposure in displacement ventilated rooms

被引:237
作者
Bjorn, E [1 ]
Nielsen, PV [1 ]
机构
[1] Univ Aalborg, Dept Bldg Technol & Struct Engn, Aalborg, Denmark
关键词
exhalation flow; contaminant distribution; personal exposure; full-scale experiments; CFD; displacement ventilation;
D O I
10.1034/j.1600-0668.2002.08126.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The influence of the human exhalation on flow fields, contaminant distributions, and personal exposures in displacement ventilated rooms is studied together with the effects of physical movement. Experiments are conducted in full-scale test rooms with life-sized breathing thermal manikins. Numerical simulations support the experiments. Air exhaled through the mouth can lock in a thermally stratified layer, if the vertical temperature gradient in breathing zone height is sufficiently large. With exhalation through the nose, exhaled air flows to the upper part of the room. The exhalation flow from both nose and mouth is able to penetrate the breathing zone of another person standing nearby. The stratification of exhaled air breaks down if there is physical movement in the room. As movement increases, the concentration distribution in the room will move towards a fully mixed situation. The protective effect of the boundary layer flow around the body of a moving person disappears at low speed, and is reduced for a seated person placed nearby due to horizontal air movements, which can also cause rebreathing of exhaled air for the seated person. The results indicate that the effect of the exhalation flow is no acute problem in most normal ventilation applications. However, exhalation and local effects caused by movement may be worth considering if one wishes to contain contaminants in certain areas, as in the case of tobacco smoking, in hospitals and clinics, or in certain industries.
引用
收藏
页码:147 / 164
页数:18
相关论文
共 24 条
  • [1] [Anonymous], 1997, ENG PHYSL BASES HUMA
  • [2] BJORN E, 2000, THESIS AALBORG U AAL
  • [3] BJORN E, 1998, P ROOMVENT 98 6 INT, V2, P133
  • [4] Bjorn E., 1999, P 3 INT M THERM MAN, P78
  • [5] Personal exposure in displacement ventilated rooms
    Brohus, H
    Nielsen, PV
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1996, 6 (03): : 157 - 167
  • [6] Brohus H., 1997, Personal exposure to contaminant sources in ventilated rooms
  • [7] Brohus H, 1996, P ROOMVENT 96, P137
  • [8] Brohus H., 1996, P IND AIR 96 JUL 21, V1, P811
  • [9] Chen C.J., 1980, Vertical Turbulent Buoyant Jets: A Review of Experimental Data
  • [10] Clark R.P., 1985, MAN HIS THERMAL ENV