Dose response effect of diaspirin crosslinked hemoglobin (DCLHb) on systemic hemodynamics and regional blood circulation in rats

被引:16
作者
Barve, A
Sen, AP
Saxena, PR
Gulati, A
机构
[1] UNIV ILLINOIS,DEPT REHABIL MED & RESTORAT MED SCI,CHICAGO,IL 60612
[2] ERASMUS UNIV ROTTERDAM,DEPT PHARMACOL,NL-3000 DR ROTTERDAM,NETHERLANDS
来源
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND IMMOBILIZATION BIOTECHNOLOGY | 1997年 / 25卷 / 1-2期
关键词
D O I
10.3109/10731199709118899
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Diaspirin crosslinked hemoglobin (DCLHb(TM), Baxter Healthcare Corporation) a hemoglobin-based blood substitute has been found to increase mean arterial pressure (MAP) in a dose limiting manner. The present study was undertaken to determine dose-dependent effects of DCLHb on systemic hemodynamics and regional blood circulation. DCLHb (10% solution) in doses of 133, 400 and 1200 mg/kg i.v. was given to urethane anaesthetized rats. Normal saline(12 ml/kg) served as a control. Cardiovascular parameters were determined using a radioactive microsphere technique. DCLHb in the doses of 133, 400 and 1200 mg/kg i.v. produced a 46%, 67% and 65% increase in MAP, respectively. Total peripheral resistance (TPR) increased significantly with 133 and 400 mg/kg dose, while cardiac output increased significantly with 400 and 1200 mg/kg dose. There was no change in heart rate. A dose of 133 mg/kg of DCLHb produced a significant decrease in blood flow to the musculoskeletal system, kidney and liver. DCLHb in the dose of 400 and 1200 mg/kg significantly increased blood flow to the heart, gastrointestinal tract (GIT), mesentery & pancreas and skin. All doses of DCLHb produced a significant increase in vascular resistance to the musculoskeletal system and liver. DCLHb in the dose of 133 mg/kg increased resistance to the GIT. heart, skin and kidneys, while the dose of 400 mg/kg increased resistance to the kidneys. A dose of 1200 mg/kg decreased coronary vascular resistance. It is concluded that cardiovascular effects appear to be different with higher (1200 mg/kg) and lower (133 mg/kg) doses of DCLHb.
引用
收藏
页码:75 / 84
页数:10
相关论文
共 19 条
[1]  
CHANG TMS, 1993, BLOOD SUBSTITUTES OX, P3
[2]  
CHATTERJEE R, 1986, J BIOL CHEM, V261, P9929
[3]  
Estep T N, 1989, Prog Clin Biol Res, V319, P325
[4]   MORPHOLOGICAL EFFECTS OF TRANSFUSIONS WITH HEMOGLOBIN-SOLUTIONS [J].
FRIEDMAN, HI ;
DEVENUTO, F .
CRITICAL CARE MEDICINE, 1982, 10 (04) :288-293
[5]   WHAT IS NITRIC-OXIDE AND WHY ARE SO MANY PEOPLE STUDYING IT [J].
GIBALDI, M .
JOURNAL OF CLINICAL PHARMACOLOGY, 1993, 33 (06) :488-496
[6]  
GULATI A, 1995, J LAB CLIN MED, V126, P559
[7]   Role of endothelin in the cardiovascular effects of diaspirin crosslinked and stroma reduced hemoglobin [J].
Gulati, A ;
Sharma, AC ;
Singh, G .
CRITICAL CARE MEDICINE, 1996, 24 (01) :137-147
[8]   EFFECT OF STROMA-FREE HEMOGLOBIN AND DIASPIRIN CROSS-LINKED HEMOGLOBIN ON THE REGIONAL CIRCULATION AND SYSTEMIC HEMODYNAMICS [J].
GULATI, A ;
SHARMA, AC ;
BURHOP, KE .
LIFE SCIENCES, 1994, 55 (10) :827-837
[9]  
GULATI A, 1994, J LAB CLIN MED, V124, P125
[10]   EFFECT OF DIASPIRIN CROSS-LINKED AND STROMA-REDUCED HEMOGLOBIN ON MEAN ARTERIAL-PRESSURE AND ENDOTHELIN-1 CONCENTRATION IN RATS [J].
GULATI, A ;
SINGH, G ;
REBELLO, S ;
SHARMA, AC .
LIFE SCIENCES, 1995, 56 (17) :1433-1442