Measurement of radiation damage on an epoxy-based optical glue

被引:5
作者
Huang, HC
Peng, KC
Sahu, SK
Ueno, K
Chang, YH
Wang, CH
Hou, WS
机构
[1] NATL TAIWAN UNIV,TAIPEI 10764,TAIWAN
[2] NATL CENT UNIV,CHUNGLI 32054,TAIWAN
[3] NATL LIEN HO COLL TECH & COMMERCE,MIAOLI,TAIWAN
[4] NATL LAB HIGH ENERGY PHYS,KEK,TSUKUBA,IBARAKI 305,JAPAN
关键词
radiation hardness; radiation damage; epoxy; glue; optical;
D O I
10.1016/S0168-9002(96)01182-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We measured the radiation damage on an optical glue called Eccobond-24, which is a candidate for CsI and EGO crystal calorimeters of the BELLE detector of the KEK B-factory. Absorption spectrophotometry in the range 300-800 nm was used to monitor the radiation damage. The maximum equivalent dose was 1.64 Mrad. The glue shows effects of damage, but is acceptable for the radiation level in the above-mentioned experiment.
引用
收藏
页码:559 / 560
页数:2
相关论文
共 5 条
[1]  
*BELL, 1995, 951 KEK BELL COLL
[2]  
*BELL, 1996, 961 KEK BELL CORP
[3]  
HOU WS, 94 BELLE
[4]   TRANSMITTANCE AND RADIATION RESISTIVITY OF OPTICAL GLUES [J].
KOBAYASHI, M ;
ISHIMOTO, S ;
SUGIMOTO, S ;
KOBAYASHI, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 305 (02) :401-405
[5]  
KOBAYASHI M, 1991, 911 KEK