Fixative-dependent increase in immunogold labeling following antigen retrieval on acrylic and epoxy sections

被引:6
作者
Brorson, SH [1 ]
机构
[1] Ulleval Hosp, Dept Pathol, N-0407 Oslo, Norway
关键词
acrylic resin; antigen retrieval; electron microscopy; epoxy resion; formaldehyde; glutaraldehyde; immunoelectron microscopy; immunoglobulin; immunogold; LR-White;
D O I
10.3109/10520299909034661
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We examined the increase in immunogold labeling of variably fixed, resin embedded tissue sections following antigen retrieval by heating in citrate solution. Fibrin clots and porcine renal tissue were fixed in glutaraldehyde, paraformaldehyde or ethanol, and specimens were embedded in LR-White or epoxy resin. Immunogold labeling was performed on ultrathin sections with anti-fibrinogen for the fibrin clots and anti-IgG for the porcine renal tissue. Immunogold labeling increased greatly after heating epoxy sections regardless of the fixative used. The ratio labeling(retrieved) /labeling(nonretrieved) (L-r/L-n) was 2.8 or higher, and the largest increases were obtained for anti-IgG, Heating induced a large increase of immunolabeling for LR-White sections only when the specimens had been fixed in paraformaldehyde (L-r/L-n = 2.2 for anti-IgG and 1.4 for antifibrinogen), LR-White sections showed decreased, insignificant or weakly increased immunolabeling of ethanol or glutaraldehyde fixed tissues following antigen retrieval. Disruption of aldehyde cross-links is not the only mechanism for antigen retrieval when epoxy sections are heated in citrate solution since large increases in immunolabeling were obtained on ethanol fixed tissue. The large heat-induced increases in immunolabeling on epoxy sections are probably caused by the disruption of chemical bonds between the epoxy resin and side groups of proteins.
引用
收藏
页码:248 / 260
页数:13
相关论文
共 27 条
[1]   MICROWAVES FOR IMMUNOHISTOCHEMISTRY [J].
BOON, ME ;
KOK, LP .
MICRON, 1994, 25 (02) :151-170
[2]   THE MORPHOLOGICAL AND IMMUNOHISTOCHEMICAL ANALYSIS OF RENAL BIOPSIES BY LIGHT AND ELECTRON-MICROSCOPY USING A SINGLE PROCESSING METHOD [J].
BOWDLER, AL ;
GRIFFITHS, DFR ;
NEWMAN, GR .
HISTOCHEMICAL JOURNAL, 1989, 21 (07) :393-402
[3]  
Brorson SH, 1999, HISTOL HISTOPATHOL, V14, P151, DOI 10.14670/HH-14.151
[4]   Improved technique for immunoelectron microscopy. How to prepare epoxy resin to obtain approximately the same immunogold labeling for epoxy sections as for acrylic sections without any etching [J].
Brorson, SH ;
Skjorten, F .
MICRON, 1996, 27 (3-4) :211-217
[5]   The combination of high-accelerator epoxy resin and antigen retrieval to obtain more intense immunolabeling on epoxy sections than on LR-white sections for large proteins [J].
Brorson, SH .
MICRON, 1998, 29 (2-3) :89-95
[6]   Comparison of the immunogold labeling of single light chains and whole immunoglobulins with anti-κ on LR-White and epoxy sections [J].
Brorson, SH .
MICRON, 1998, 29 (06) :439-443
[7]   Immunoelectron microscopy on epoxy sections without deplasticizing to detect glomerular immunoglobulin and complement deposits in renal diseases [J].
Brorson, SH ;
Strom, EH ;
Skjorten, F .
APMIS, 1997, 105 (02) :139-149
[8]   Bovine serum albumin (BSA) as a reagent against non-specific immunogold labeling on LR-White and epoxy resin [J].
Brorson, SH .
MICRON, 1997, 28 (03) :189-195
[9]  
Brorson SH, 1998, HISTOL HISTOPATHOL, V13, P275, DOI 10.14670/HH-13.275
[10]   The theoretical relationship of immunogold labeling on acrylic sections and epoxy sections [J].
Brorson, SH ;
Skjorten, F .
MICRON, 1996, 27 (3-4) :193-201