Preliminary evaluation of the cadmium concentration in seawater of the Salvador City, Brazil

被引:30
作者
Ferreira, AC [1 ]
Costa, ACS [1 ]
Korn, MGA [1 ]
机构
[1] Univ Fed Bahia, Inst Quim, Grp Pesquisa Quim Analit, BR-40170290 Salvador, BA, Brazil
关键词
preconcentration; cadmium; PAR;
D O I
10.1016/j.microc.2004.03.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for preconcentration and determination of trace amounts of cadmium in high saline samples is described. It is based on the adsorption of the metal in the activated carbon as complex cadmium(II)-4-(2-pyridylazo-resorcinol) (PAR). The final determination was carried by flame atomic absorption spectrometry (FAAS). The optimization of extraction parameters such as the pH effect, PAR mass, activated carbon mass and shaking time was carried out using a two-level full factorial design (2(4)) and two Doehlert matrix designs. The results of the factorial design, considering the analysis of variance (ANOVA), demonstrate that all these factors are statistically significant, as well as the interactions (pH x PAR mass), (pH x activated carbon mass) and (activated carbon mass x shaking time). The final optimization was carried out using Doehlert matrix designs considering the results of the factorial design. The recoveries were quantitative (96.0-106.7%) for seawater samples spiked with Cd at concentrations of 0.125 and 0.625 mug l(-1). A preconcentration factor of 149 was obtained. The effect of diverse metallic ions on the proposed procedure was investigated too. The procedure was used for cadmium determination in surface seawater samples collected in Salvador City, Brazil. The cadmium content in the analysed samples varies from 0.035 to 0.17 mug l(-1). These results are agreement with other data reported in the literature. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:77 / 83
页数:7
相关论文
共 29 条
[1]   The retention of metal species by different solid sorbents - Mechanisms for heavy metal speciation by sequential three column uptake [J].
Abollino, O ;
Aceto, M ;
Sarzanini, C ;
Mentasti, E .
ANALYTICA CHIMICA ACTA, 2000, 411 (1-2) :223-237
[2]   On-line preconcentration and determination of copper, lead and chromium(VI) using unloaded polyurethane foam packed column by flame atomic absorption spectrometry in natural waters and biological samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2002, 58 (05) :831-840
[3]   A low-cost flame atomic absorption spectrometry method for determination of trace metals in aqueous samples [J].
Carasek, E .
TALANTA, 2000, 51 (01) :173-178
[4]   Flow injection on-line coprecipitation-preconcentration system using copper(II) diethyldithiocarbamate as carrier for flame atomic absorption spectrometric determination of cadmium, lead and nickel in environmental samples [J].
Chen, HW ;
Jin, JC ;
Wang, YF .
ANALYTICA CHIMICA ACTA, 1997, 353 (2-3) :181-188
[5]   SIMULTANEOUS MULTIELEMENT ANALYSIS FOR TRACE-METALS IN SEA-WATER BY INDUCTIVELY-COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY AFTER BATCH PRECONCENTRATION ON A CHELATING RESIN [J].
CHENG, CJ ;
AKAGI, T ;
HARAGUCHI, H .
ANALYTICA CHIMICA ACTA, 1987, 198 :173-181
[6]   Determination of some trace metals in water and sediment samples by flame atomic absorption spectrometry after coprecipitation with cerium (IV) hydroxide [J].
Divrikli, Ü ;
Elçi, L .
ANALYTICA CHIMICA ACTA, 2002, 452 (02) :231-235
[7]  
Doehlert D.H., 1970, Appl. Stat, V19, P231
[8]   Application of three-variables Doehlert matrix for optimisation of an on-line pre-concentration system for zinc determination in natural water samples by flame atomic absorption spectrometry [J].
dos Santos, WNL ;
Santos, CMC ;
Ferreira, SLC .
MICROCHEMICAL JOURNAL, 2003, 75 (03) :211-221
[9]   Determination of trace amounts of some metals in samples with high salt content by atomic absorption spectrometry after cobalt-diethyldithiocarbamate coprecipitation [J].
Elci, L ;
Sahin, U ;
Oztas, S .
TALANTA, 1997, 44 (06) :1017-1023
[10]   Determination of cadmium in mussels by flame atomic absorption spectrometry with preconcentration on a chelating resin in a flow injection system [J].
Enríquez-Domínguez, MF ;
Yebra-Biurrun, MC ;
Bermejo-Barrera, MP .
ANALYST, 1998, 123 (01) :105-108