Diffusion tensor imaging using single-shot SENSE-EPI

被引:221
作者
Bammer, R
Auer, M
Keeling, SL
Augustin, M
Stables, LA
Prokesch, RW
Stollberger, R
Moseley, ME
Fazekas, F
机构
[1] Stanford Univ, Dept Radiol, Lucas MRS I Ctr, Stanford, CA 94305 USA
[2] Karl Franzens Univ Graz, Magnet Resonance Inst, Graz, Austria
[3] Karl Franzens Univ Graz, Dept Neurol, Graz, Austria
[4] Karl Franzens Univ Graz, Dept Math, Graz, Austria
[5] Karl Franzens Univ Graz, Dept Radiol, Graz, Austria
关键词
magnetic resonance imaging; diffusion tensor imaging; brain; white matter; brain morphology;
D O I
10.1002/mrm.10184
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SENSitivity Encoding (SENSE) greatly enhances the quality of diffusion-weighted echo-planar imaging (EPI) by reducing blurring and off-resonance artifacts. Such improvement would also be desirable for diffusion tensor imaging (DTI), but measures derived from the diffusion tensor can be extremely sensitive to any kind of image distortion. Whether DTI is feasible in combination with SENSE has not yet been explored, and is the focus of this study. Using a SENSE-reduction factor of 2, DTI scans in eight healthy volunteers were carried out with regular- and high-resolution acquisition matrices. To further improve the stability of the SENSE reconstruction, a new coil-sensitivity estimation technique based on variational calculus and the principles of matrix regularization was applied. With SENSE, maps of the trace of the diffusion tensor and of fractional anisotropy (FA) had improved spatial resolution and less geometric distortion. Overall, the geometric distortions were substantially removed and a significant resolution enhancement was achieved with almost the same scan time as regular EPI. DTI was even possible without the use of quadrature body coil (QBC) reference scans. Geometry-factor-related noise enhancement was only discernible in maps generated with higher-resolution matrices. Error boundaries for residual fluctuations in SENSE reconstructions are discussed. Our results suggest that SENSE can be combined with DTI and may present an important adjunct for future neuroimaging applications of this technique. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:128 / 136
页数:9
相关论文
共 32 条
  • [1] Bammer R, 2000, MAGNET RESON MED, V44, P583, DOI 10.1002/1522-2594(200010)44:4<583::AID-MRM12>3.0.CO
  • [2] 2-O
  • [3] Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)
    Bammer, R
    Keeling, SL
    Augustin, M
    Pruessmann, KP
    Wolf, R
    Stollberger, R
    Hartung, HP
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 548 - 554
  • [4] BAMMER R, 2000, P 8 ANN M ISMRM DENV, P1503
  • [5] BAMMER R, 2001, P 9 ANN M ISMRM GLAS, P508
  • [6] Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
  • [7] 2-O
  • [8] MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING
    BASSER, PJ
    MATTIELLO, J
    LEBIHAN, D
    [J]. BIOPHYSICAL JOURNAL, 1994, 66 (01) : 259 - 267
  • [9] De Crespigny A J., 1998, Proceedings of the International Society for Magnetic Resonance in Medicine, page, P661
  • [10] Diffusion tensor magnetic resonance imaging in multiple sclerosis
    Filippi, M
    Cercignani, M
    Inglese, M
    Horsfield, MA
    Comi, G
    [J]. NEUROLOGY, 2001, 56 (03) : 304 - 311