Classification of thoracic and lumbar spine fractures: problems of reproducibility - A study of 53 patients using CT and MRI

被引:154
作者
Oner, FC
Ramos, LMP
Simmermacher, RKJ
Kingma, PTD
Diekerhof, CH
Dhert, WJA
Verbout, AJ
机构
[1] Univ Utrecht Hosp, NL-3508 GA Utrecht, Netherlands
[2] Univ Utrecht, Med Ctr, Dept Orthoped, Utrecht, Netherlands
[3] Univ Utrecht, Med Ctr, Dept Radiol, Utrecht, Netherlands
[4] Univ Utrecht, Med Ctr, Dept Gen Surg, Utrecht, Netherlands
关键词
spine; thoracolumbar; spine fractures; classification; MRI;
D O I
10.1007/s00586-001-0364-8
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Reproducibility of fracture classification systems in general has been a matter of controversy. The reproducibility of spinal fracture classifications has not been sufficiently studied. We studied the inter-observer and intra-observer reproducibility of the Magerl (AO) classification using radiograms, CTs and MRIs of 53 patients. We compared this classification with the older and simpler Denis classification. Five observers classified the fractures, first using the radiograms and CTs and, 6 weeks later, with radiograms and MRIs. Three of the observers repeated the readings after 3 months. Three observers also classified the fractures according to Denis. Agreement was measured using Cohen's kappa test. The type (A, B, C) classification of the AO system was fairly reproducible with CTs. With MRI this was only moderate. Group subclassification of the types yielded higher kappa values, corresponding to substantial agreement. The agreement was, in general, better with the Denis classification, but the variance was higher due to the difficulty of finding proper categories for some injury patterns. Although the AO classification allows proper registration of all kinds of injury, the reproducibility, especially at the type level, is problematic. Use of MRI and better definition of the distinctive properties of the three different types may enhance the reproducibility of the scheme.
引用
收藏
页码:235 / 245
页数:11
相关论文
共 31 条
[1]
Classification of distal radius fractures: An analysis of interobserver reliability and intraobserver reproducibility [J].
Andersen, DJ ;
Blair, WF ;
Steyers, CM ;
Adams, BD ;
ElKhouri, GY ;
Brandser, EA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (04) :574-582
[2]
EVANS CLASSIFICATION OF TROCHANTERIC FRACTURES - AN ASSESSMENT OF THE INTEROBSERVER AND INTRAOBSERVER RELIABILITY [J].
ANDERSEN, E ;
JORGENSEN, LG ;
HEDEDAM, LT .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1990, 21 (06) :377-378
[3]
OLDER CLASSIFICATION OF COLLES FRACTURES - GOOD INTRAOBSERVER AND INTEROBSERVER REPRODUCIBILITY IN 185 CASES [J].
ANDERSEN, GR ;
RASMUSSEN, JB ;
DAHL, B ;
SOLGAARD, S .
ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (05) :463-464
[4]
Blauth M, 1999, ORTHOPADE, V28, P662, DOI 10.1007/PL00003655
[5]
Bohler L, 1943, TECHNIK KNOCHENBRUCH, P9
[6]
INTEROBSERVER AGREEMENT IN THE CLASSIFICATION OF OPEN FRACTURES OF THE TIBIA - THE RESULTS OF A SURVEY OF 245 ORTHOPEDIC SURGEONS [J].
BRUMBACK, RJ ;
JONES, AL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (08) :1162-1166
[8]
DAWKINS R, 1991, BLIND WATCHMAKER, P81
[10]
A critical assessment of factors influencing reliability in the classification of fractures, using fractures of the tibial plafond as a model [J].
Dirschl, DR ;
Adams, GL .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (07) :471-476