Influence of a nonionic, iso-osmolar contrast medium (iodixanol) versus an ionic, low-osmolar contrast medium (ioxaglate) on major adverse cardiac events in patients undergoing percutaneous transluminal coronary angioplasty a multicenter, randomized, double-blind study

被引:69
作者
Bertrand, ME
Esplugas, E
Piessens, J
Rasch, W
机构
[1] Univ Lille, Div Cardiol, Inst Heart, Lille, France
[2] Hosp Bellvitge Princeps Espanya, Barcelona, Spain
[3] Nycomed Amersham, Oslo, Norway
[4] Univ Ziekenhuis Gasthuisberg, Louvain, Belgium
关键词
contrast media; angioplasty; angiography; stents;
D O I
10.1161/01.CIR.101.2.131
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The potential merits and disadvantages of the use of ionic or nonionic contrast media in patients undergoing percutaneous transluminal coronary angioplasty (PTCA) have been the subjects of controversy. The present study was designed to evaluate the possible influence of both types of contrast media on major adverse cardiac events (MACE) in patients undergoing PTCA. Methods and Results-In a randomized, parallel-group, double-blind study, 1411 patients received either iodixanol (a nonionic, iso-osmolar contrast medium) or ioxaglate (an ionic, low-osmolar contrast medium) during PTCA. A standardized anticoagulation regimen was followed. Patients were monitored in the hospital for 2 days and followed-up at 1 month. The primary end point, a composite of MACE (death, stroke, myocardial infarction, coronary artery bypass grafting, and re-PTCA) after 2 days, occurred in 4.3% of the total population, with no statistically significant difference between groups (iodixanol, 4.7%; ioxaglate, 3.9%; P=0.45). Further, between 2-day and 1-month follow-ups, no significant difference (P=0.27) existed between the groups in the rates of MACE. Hypersensitivity reactions (P=0.007) and adverse drug reactions (P=0.002) were significantly less frequent in the iodixanol group. The only significant predicting factors for the occurrence of MACE were dissection/abrupt closure and country. Conclusions-No significant differences were observed between the iodixanol and ioxaglate groups with regard to MACE, although hypersensitivity and adverse drug reactions were significantly less frequent in patients who received iodixanol.
引用
收藏
页码:131 / 136
页数:6
相关论文
共 31 条
  • [1] THROMBOGENICITY OF IONIC AND NONIONIC CONTRAST-MEDIA TESTED IN A LASER-INDUCED RAT THROMBOSIS MODEL
    AGUEJOUF, O
    DOUTREMEPUICH, F
    AZOUGAGH, OF
    DOUTREMEPUICH, C
    [J]. THROMBOSIS RESEARCH, 1995, 77 (03) : 259 - 269
  • [2] EFFECTS OF IONIC AND NONIONIC CONTRAST-MEDIA ON IN-VITRO AND IN-VIVO PLATELET ACTIVATION
    ALBANESE, JR
    VENDITTO, JA
    PATEL, GC
    AMBROSE, JA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (14) : 1059 - 1063
  • [3] INVIVO EFFECTS OF NONIONIC AND IONIC CONTRAST-MEDIA ON BETA-THROMBOGLOBULIN AND FIBRINOPEPTIDE LEVELS
    ARORA, R
    KHANDELWAL, M
    GOPAL, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (07) : 1533 - 1536
  • [4] A COMPARISON OF NONIONIC, LOW-OSMOLALITY RADIOCONTRAST AGENTS WITH IONIC, HIGH-OSMOLALITY AGENTS DURING CARDIAC-CATHETERIZATION
    BARRETT, BJ
    PARFREY, PS
    VAVASOUR, HM
    ODEA, F
    KENT, G
    STONE, E
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (07) : 431 - 436
  • [5] Barstad RM, 1996, THROMB HAEMOSTASIS, V75, P685
  • [6] EFFECT OF IOXAGLATE - AN IONIC LOW-OSMOLAR CONTRAST-MEDIUM - ON FIBRIN POLYMERIZATION IN-VITRO
    BRASS, O
    BELLEVILLE, J
    SABATTIER, V
    COROT, C
    [J]. BLOOD COAGULATION & FIBRINOLYSIS, 1993, 4 (05) : 689 - 697
  • [7] PROFOUND PLATELET DEGRANULATION IS AN IMPORTANT SIDE-EFFECT OF SOME TYPES OF CONTRAST-MEDIA USED IN INTERVENTIONAL CARDIOLOGY
    CHRONOS, NAF
    GOODALL, AH
    WILSON, DJ
    SIGWART, U
    BULLER, NP
    [J]. CIRCULATION, 1993, 88 (05) : 2035 - 2044
  • [8] In vitro comparison of the effects of contrast media on coagulation and platelet activation
    Corot, C
    Chronos, N
    Sabattier, V
    [J]. BLOOD COAGULATION & FIBRINOLYSIS, 1996, 7 (06) : 602 - 608
  • [9] ELOY R, 1991, Clinical Materials, V7, P89, DOI 10.1016/0267-6605(91)90045-H
  • [10] RISK OF THROMBOSIS DURING CORONARY ANGIOPLASTY WITH LOW OSMOLALITY CONTRAST-MEDIA
    ESPLUGAS, E
    CEQUIER, A
    JARA, F
    MAURI, J
    SOLER, T
    SALA, J
    SABATE, X
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (10) : 1020 - 1024