Discrepancy between latex and ELISA D-dimer values in sepsis may be caused by human neutrophil elastase

被引:9
作者
BachGansmo, ET
Strand, O
Godal, HC
Wisloff, F
Skjonsberg, OH
机构
[1] UNIV OSLO, ULLEVAL HOSP, DEPT PULM MED, OSLO, NORWAY
[2] UNIV OSLO, ULLEVAL HOSP, HEMATOL RES LAB, OSLO, NORWAY
[3] UNIV OSLO, ULLEVAL HOSP, DEPT INFECT DIS, OSLO, NORWAY
关键词
elastase; sepsis; D-dimer; latex agglutination test; ELISA test;
D O I
10.1016/S0049-3848(97)00057-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We have recently shown that D-dimers are degraded by human neutrophil elastase (HNE) in vitro, causing rapid decrease in the D-dimer levels measured by a Latex test, but not with an ELISA test employing the same monoclonal antibody against D-dimer. To see if such discrepant D-dimer concentrations occurred in patients with high HNE concentration, we examined 80 plasma samples from 8 patients with sepsis with a Latex and an ELISA test and calculated the ratio between the D-dimer values obtained with the two tests. Twenty healthy pregnant and twenty pre-eclamptic patients, who are known to have raised D-dimer but low HNE concentrations, were chosen as controls. HNE levels were estimated by determining the HNE-alpha 1-proteinase inhibitor complex (HNE-A1PI) concentration. HNE-A1PI concentration was increased in sepsis patients compared with pre-eclamptic patients (p<0.0005) and healthy pregnant women (p<0.0005). In sepsis patients, the D-dimer results were skewed towards lower ratios between Latex and ELISA values compared to pre-eclamptic patients (p=0.008) and healthy pregnant women (p=0.0001). In plasma samples from patients with the largest discrepancy between Latex and ELISA D-dimer values, Western blotting with immunostaining indicated degradation of D-dimers to D-like fragments similar to those observed following degradation of cross-linked fibrin by HNE in vitro. We conclude that in sepsis patients there is a marked discrepancy between Latex and ELISA D-dimer values that may be caused by HNE. In such patients Latex D-dimer assays may cause severe underestimation of fibrinolysis. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:141 / 152
页数:12
相关论文
共 29 条
[1]  
[Anonymous], BRIT MED J
[2]   IMPAIRED COAGULATION OF FIBRINOGEN DUE TO DIGESTION OF THE C-TERMINAL END OF THE A-ALPHA-CHAIN BY HUMAN NEUTROPHIL ELASTASE [J].
BACHGANSMO, ET ;
HALVORSEN, S ;
GODAL, HC ;
SKJONSBERG, OH .
THROMBOSIS RESEARCH, 1994, 73 (01) :61-68
[3]   DEGRADATION OF THE ALPHA-CHAIN OF FIBRIN BY HUMAN NEUTROPHIL ELASTASE REDUCES THE STIMULATING EFFECT OF FIBRIN ON PLASMINOGEN ACTIVATION [J].
BACHGANSMO, ET ;
HALVORSEN, S ;
GODAL, HC ;
SKJONSBERG, OH .
THROMBOSIS RESEARCH, 1994, 75 (03) :307-317
[4]   D-dimers are degraded by human neutrophil elastase [J].
BachGansmo, ET ;
Halvorsen, S ;
Godal, HC ;
Skjonsberg, OH .
THROMBOSIS RESEARCH, 1996, 82 (02) :177-186
[5]  
BELL WR, 1980, JOHNS HOPKINS MED J, V146, P289
[6]  
BUDZYNSKI AZ, 1979, BLOOD, V54, P794
[7]   PROTEOLYSIS BY NEUTROPHILS - RELATIVE IMPORTANCE OF CELL-SUBSTRATE CONTACT AND OXIDATIVE INACTIVATION OF PROTEINASE-INHIBITORS INVITRO [J].
CAMPBELL, EJ ;
SENIOR, RM ;
MCDONALD, JA ;
COX, DL .
JOURNAL OF CLINICAL INVESTIGATION, 1982, 70 (04) :845-852
[8]  
COHEN JR, 1990, AM SURGEON, V56, P665
[9]  
GAFFNEY PJ, 1972, LANCET, V1, P1422
[10]   NEUTROPHIL ACTIVATION IN PREGNANCY-INDUCED HYPERTENSION [J].
GREER, IA ;
HADDAD, NG ;
DAWES, J ;
JOHNSTONE, FD ;
CALDER, AA .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1989, 96 (08) :978-982