Strain and temperature effects on erbium-doped fiber for decay-time based sensing

被引:26
作者
Arnaud, A [1 ]
Forsyth, DI
Sun, T
Zhang, ZY
Grattan, KTV
机构
[1] Univ Republ, Fac Ingn, Inst Ingn Elect, Montevideo, Uruguay
[2] City Univ London, Dept Elect Elect & Informat Engn, London EC1V 0HB, England
关键词
D O I
10.1063/1.1150169
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An experimental investigation into the strain and temperature sensitivity of the fluorescence decay time in commercial erbium-doped optical fiber has been carried out. Results show that a strain effect on the performance of temperature-based sensors using such fiber is larger than that for neodymium-doped fiber, but a little smaller than is seen in similar ytterbium-doped material. For the materials studied, the relative change in lifetime ranges from about 5x10(-7) (for Yb) to 14x10(-7) (for Nd) mu epsilon(-1) and the associated error in the temperature measurement ranges from 1.8x10(-3) (for Nd) to 6.1x10(-3) K mu epsilon(-1) for the Yb sample used. The application to simultaneous strain and temperature monitoring is discussed. (C) 2000 American Institute of Physics. [S0034-6748(00)03701-1].
引用
收藏
页码:104 / 108
页数:5
相关论文
共 10 条
[1]   THE ABSORPTION AND FLUORESCENCE-SPECTRA OF RARE-EARTH IONS IN SILICA-BASED MONOMODE FIBER [J].
AINSLIE, BJ ;
CRAIG, SP ;
DAVEY, ST .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1988, 6 (02) :287-293
[2]  
Grattan K. T. V., 1995, FIBER OPTIC FLUORESC
[3]  
Grattan K. T. V., 1999, OPTICAL FIBER SENSOR, V4
[4]  
Jones J. D. C., 1997, OSA TECHNICAL DIGEST, V16, P36
[5]  
LIU T, 1998, EUROSENSORS, V12, P323
[6]   HIGH DYNAMIC-RANGE TEMPERATURE POINT SENSOR USING GREEN FLUORESCENCE INTENSITY RATIO IN ERBIUM-DOPED SILICA FIBER [J].
MAURICE, E ;
MONNOM, G ;
OSTROWSKY, DB ;
BAXTER, GW .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1995, 13 (07) :1349-1353
[7]   Intrinsic strain and temperature characteristics of Yb-doped silica-based optical fibers [J].
Sun, T ;
Zhang, ZY ;
Grattan, KTV ;
Palmer, AW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (02) :1447-1451
[8]   Intrinsic doped fluorescence decay-time based measurements - Strain and temperature characteristics for sensor purposes [J].
Sun, T ;
Zhang, ZY ;
Grattan, KTV ;
Palmer, AW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (12) :4186-4190
[9]   Fluorescence decay-time characteristics of erbium-doped optical fiber at elevated temperatures [J].
Zhang, ZY ;
Grattan, KTV ;
Palmer, AW ;
Meggitt, BT ;
Sun, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (07) :2764-2766
[10]   PHASE-LOCKED DETECTION OF FLUORESCENCE LIFETIME [J].
ZHANG, ZY ;
GRATTAN, KTV ;
PALMER, AW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (09) :2531-2540