Dopamine and glucose sensors based on glassy carbon electrodes modified with melanic polymers

被引:19
作者
González, R
Sánchez, A
Chicharro, M
Rubianes, MD
Rivas, GA
机构
[1] Univ Nacl Cordoba, INFIQC, Dept Quim Fis, Fac Ciencias Quim, RA-5000 Cordoba, Argentina
[2] Univ Autonoma Madrid, Fac Ciencias, Dept Quim Analit & Analisis Instrumental, Univ Cantoblanco, E-28049 Madrid, Spain
关键词
polymer; melanin; flow injection; glassy carbon; dopamine; dopac; ascorbic acid; glucose biosensor; metallized electrode; platinum;
D O I
10.1002/elan.200302939
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work deals with the study of polymers electrogenerated from different catechols at glassy carbon electrodes and the analytical applications of the resulting modified electrodes for dopamine quantification and glucose biosensing. The electropolymerization was performed from a 3.0 x 10(-3) M catechol solution (catechol, dopamine, norepinephrine, epinephrine or L-dopa in a 0.050 M phosphate buffer pH 7.40) by applying 1.00 V for 60 min. The properties of the polymers are very dependent on the nature of the catechol, L-dopa being the best. Glassy carbon electrodes modified with melanic polymers electrogenerated from L-dopa and norepinephrine were found to be suitable for dopamine determinations in flow systems, although the behavior was highly dependent on the nature of the monomer. Detection limits of 5.0 nM dopamine and interferences of 9.0 and 2.6% for 5.0 x 10(-4) M ascorbic acid and 5.0 x 10(-5) M dopac, respectively, were obtained at the glassy carbon electrode modified with a melanin-type polymer generated from L-dopa (using 1.0 x 10(-3) M AA in the measurement solution). The advantages of using a melanin-type polymer generated from dopamine to improve the selectivity of glucose biosensors based on carbon paste electrodes containing Pt and glucose oxidase (GOx) are also discussed. The resulting bioelectrodes combines the high sensitivity of metallized electrodes with the selectivity given by the polymeric layer. They exhibit excellent performance for glucose with a rapid response (around 10 seconds per sample), a wide linear range (up to 2.5 x 10(-2) M glucose), low detection limits (143 muM) and a highly reproducible response (R.S.D of 4.9%). The bioelectrodes are highly stable and almost free from the interference of large excess of easily oxidizable compounds found in biological fluids, such as ascorbic acid (AA), uric acid (UA) and acetaminophen.
引用
收藏
页码:1244 / 1253
页数:10
相关论文
共 18 条
[1]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[2]  
BRUN A, 1974, J ELECTROANAL CHEM, V49, P287, DOI 10.1016/S0022-0728(74)80236-6
[3]   BIOCATALYSIS WITH POLYPHENOL OXIDASE - A REVIEW [J].
BURTON, SG .
CATALYSIS TODAY, 1994, 22 (03) :459-487
[4]   The electrocatalytic properties of biological molecules using polymerized luminol film-modified electrodes [J].
Chen, SM ;
Lin, KC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 523 (1-2) :93-105
[5]   Polyeugenol-modified platinum electrode for selective detection of dopamine in the presence of ascorbic acid [J].
Ciszewski, A ;
Milczarek, G .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1055-1061
[6]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456
[7]   GLUCOSE ENZYME ELECTRODE PREPARATION BY THE CODEPOSITION OF PLATINUM AND GLUCOSE-OXIDASE ONTO GLASSY-CARBON [J].
GUNASINGHAM, H ;
TAN, CB .
ELECTROANALYSIS, 1989, 1 (03) :223-227
[8]   Amperometric glucose biosensors based on composite polymeric structures to prevent interferences [J].
Mailley, P ;
Cosnier, S ;
Coche-Guérente, L .
ANALYTICAL LETTERS, 2000, 33 (09) :1733-1753
[9]   Simultaneous measurement at dopamine and ascorbate at their physiological levels using voltammetric microprobe based on overoxidized poly(1,2-phenylenediamine)-coated carbon fiber [J].
Mo, JW ;
Ogorevc, B .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1196-1202
[10]   Simultaneous electroanalysis of dopamine and ascorbic acid using poly (N,N-dimethylaniline)-modified electrodes [J].
Roy, PR ;
Okajima, T ;
Ohsaka, T .
BIOELECTROCHEMISTRY, 2003, 59 (1-2) :11-19