Pulsed electrochemical detection of thiols and disulfides following capillary electrophoresis

被引:44
作者
Owens, GS [1 ]
LaCourse, WR [1 ]
机构
[1] UNIV MARYLAND BALTIMORE CTY,DEPT CHEM & BIOCHEM,BALTIMORE,MD 21250
来源
JOURNAL OF CHROMATOGRAPHY B | 1997年 / 695卷 / 01期
关键词
thiols; disulfides; thiocompounds;
D O I
10.1016/S0378-4347(97)00096-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Pulsed electrochemical detection (PED) following capillary electrophoresis (CE) has been applied to the direct detection of thiocompounds. Both reduced and oxidized thiol moieties are detected without the need of derivatization. Thiocompounds can be detected over a wide range of pH conditions (i.e., pH 0-14), and except for pH, their response is relatively unperturbed by buffer composition. Integrated pulsed amperometric detection (IPAD) results in more stable baselines, eliminates oxide-induced artifacts, and yields lower limits of detection than other PED waveforms. Mass detection limits using optimized IPAD waveforms are typically 2 pg (5 fmol) or less. The high selectivity of PED for thiocompounds reduces sample preparation and produces simpler electropherograms of complex samples containing these biologically significant compounds.
引用
收藏
页码:15 / 25
页数:11
相关论文
共 28 条
[1]  
[Anonymous], 1980, Electrochemical Methods
[2]   MULTIPLICITY OF ANODIC AND CATHODIC CURRENT PEAKS OBSERVED DURING POTENTIODYNAMIC PERTURBATIONS OF GOLD-SODIUM HYDROXIDE SOLUTION INTERFACES [J].
CORDOVA, R ;
MARTINS, ME ;
ARVIA, AJ .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1979, 126 (07) :1172-1176
[3]   ELECTROCHEMICAL DETECTION IN MICROCOLUMN SEPARATIONS [J].
EWING, AG ;
MESAROS, JM ;
GAVIN, PF .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :A527-A537
[4]   ADSORPTION STUDY OF CYSTEINE, N-ACETYLCYSTEAMINE, CYSTEINESULFINIC ACID AND CYSTEIC ACID ON A POLYCRYSTALLINE GOLD ELECTRODE [J].
FAWCETT, WR ;
FEDURCO, M ;
KOVACOVA, Z ;
BORKOWSKA, Z .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 368 (1-2) :275-280
[5]   OXIDATION OF CYSTEINE, CYSTEINESULFINIC ACID AND CYSTEIC ACID ON A POLYCRYSTALLINE GOLD ELECTRODE [J].
FAWCETT, WR ;
FEDURCO, M ;
KOVACOVA, Z ;
BORKOWSKA, Z .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 368 (1-2) :265-274
[6]   DETERMINATION OF THIOLS BY CAPILLARY ELECTROPHORESIS WITH ELECTROCHEMICAL DETECTION USING A PALLADIUM FIELD-DECOUPLER AND CHEMICALLY-MODIFIED ELECTRODES [J].
HUANG, XJ ;
KOK, WT .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :347-353
[7]   PULSED ELECTROCHEMICAL DETECTION AT NOBLE-METAL ELECTRODES IN LIQUID-CHROMATOGRAPHY [J].
JOHNSON, DC ;
LACOURSE, WR .
ELECTROANALYSIS, 1992, 4 (04) :367-380
[8]   LIQUID-CHROMATOGRAPHY WITH PULSED ELECTROCHEMICAL DETECTION AT GOLD AND PLATINUM-ELECTRODES [J].
JOHNSON, DC ;
LACOURSE, WR .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :A589-A597
[9]  
KORYTA J, 1968, J ELECTROANAL CHEM, V17, P177
[10]  
KORYTA J, 1968, J ELECTROANAL CHEM, V17, P185, DOI 10.1016/0368-1874(68)80021-8