Heart rate-dependence of arterial distensibility in vivo

被引:170
作者
Mangoni, AA
Mircoli, L
Giannattasio, C
Ferrari, AU
Mancia, G
机构
[1] UNIV MILAN,OSPED MAGGIORE,CTR FISIOL CLIN & IPERTENS,I-20122 MILAN,ITALY
[2] OSPED SAN GERARDO,CATTEDRA MED INTERNA,MONZA,ITALY
[3] OSPED SEREGNO AZ,USSL 30,DIV CARDIORIABILITAZ,DESIO,ITALY
关键词
echo-tracking; arterial compliance; arterial distensibility; heart rate; atrial pacing; blood vessels; rat;
D O I
10.1097/00004872-199607000-00013
中图分类号
R6 [外科学];
学科分类号
1002 [临床医学]; 100210 [外科学];
摘要
Objectives Viscous and inertial components contribute to arterial distensibility and compliance in vitro. The purpose of our study was to determine whether this phenomenon is of relevance in vivo, namely, whether arterial compliance is altered by an increase in heart rate. Design Arterial diameter was assessed by an echo-Doppler device in a common carotid and femoral artery, namely, in a large elastic and a muscle artery. The studies were performed in 12-week-old pentobarbitone-anaesthetized Wistar-Kyoto rats subjected to atrial pacing via a transjugular unipolar catheter at five different randomly sequenced rates (280, 310, 340, 370 and 400 beats/min), After each stage, spontaneous sinus rhythm was allowed to return, Blood pressure was measured via a catheter inserted into the carotid or femoral artery contralateral to the vessels in which the diameter was measured, Arterial compliance and distensibility values were derived according to the Langewouters formula. Results A progressive increase in heart rate caused by pacing was accompanied by progressive and marked reductions in carotid artery compliance and distensibility, When quantified by the area under the distensibility-pressure or compliance-pressure curve the reduction was in the range 15-43%. Although a tendency to a similar phenomenon was observed in the femoral artery, in the latter vessel the reduction in distensibility and compliance was less marked and statistically insignificant. Conclusions In the anaesthetized rat acute increases in heart rate are accompanied by reductions in arterial compliance and distensibility. The effect is greater in elastic than in muscle arteries.
引用
收藏
页码:897 / 901
页数:5
相关论文
共 16 条
[1]
ARTERIAL-WALL MECHANICS IN CONSCIOUS DOGS - ASSESSMENT OF VISCOUS, INERTIAL, AND ELASTIC-MODULI TO CHARACTERIZE AORTIC-WALL BEHAVIOR [J].
ARMENTANO, RL ;
BARRA, JG ;
LEVENSON, J ;
SIMON, A ;
PICHEL, RH .
CIRCULATION RESEARCH, 1995, 76 (03) :468-478
[2]
DYNAMIC ELASTIC PROPERTIES OF ARTERIAL WALL [J].
BERGEL, DH .
JOURNAL OF PHYSIOLOGY-LONDON, 1961, 156 (03) :458-&
[3]
SYMPATHECTOMY AND CARDIOVASCULAR SPECTRAL COMPONENTS IN CONSCIOUS NORMOTENSIVE RATS [J].
DAFFONCHIO, A ;
FRANZELLI, C ;
RADAELLI, A ;
CASTIGLIONI, P ;
DIRIENZO, M ;
MANCIA, G ;
FERRARI, AU .
HYPERTENSION, 1995, 25 (06) :1287-1293
[4]
Dobrin P.B., 1983, HDB PHYSL CARDIOVASC, VIII, P65
[5]
ANGIOTENSIN-CONVERTING ENZYME-INHIBITION AND RADIAL ARTERY COMPLIANCE IN PATIENTS WITH CONGESTIVE-HEART-FAILURE [J].
GIANNATTASIO, C ;
FAILLA, M ;
STELLA, ML ;
MANGONI, AA ;
TURRINI, D ;
CARUGO, S ;
POZZI, M ;
GRASSI, G ;
MANCIA, G .
HYPERTENSION, 1995, 26 (03) :491-496
[6]
ALTERATIONS OF RADIAL ARTERY COMPLIANCE IN PATIENTS WITH CONGESTIVE-HEART-FAILURE [J].
GIANNATTASIO, C ;
FAILLA, M ;
STELLA, ML ;
MANGONI, AA ;
CARUGO, S ;
POZZI, M ;
GRASSI, G ;
MANCIA, G .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (05) :381-385
[7]
CONDUIT ARTERY COMPLIANCE AND DISTENSIBILITY ARE NOT NECESSARILY REDUCED IN HYPERTENSION [J].
HAYOZ, D ;
RUTSCHMANN, B ;
PERRET, F ;
NIEDERBERGER, M ;
TARDY, Y ;
MOOSER, V ;
NUSSBERGER, J ;
WAEBER, B ;
BRUNNER, HR .
HYPERTENSION, 1992, 20 (01) :1-6
[8]
PRESSURE DIAMETER RELATIONSHIPS OF SEGMENTS OF HUMAN FINGER ARTERIES [J].
LANGEWOUTERS, GJ ;
ZWART, A ;
BUSSE, R ;
WESSELING, KH .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1986, 7 (01) :43-56
[9]
VARIABILITY OF THE VISCOELASTIC CONSTANTS ALONG THE AORTIC AXIS OF THE DOG [J].
LAWTON, RW .
CIRCULATION RESEARCH, 1960, 8 (02) :381-389
[10]
MANCIA G, 1983, HDB PHYSL CARDIOVASC, V3, P755