Reduced forward output states affect the left ventricular opacification of intravenously administered Albunex

被引:20
作者
Gandhok, NK [1 ]
Block, R [1 ]
Ostoic, T [1 ]
Rawal, M [1 ]
Hickle, P [1 ]
Devries, S [1 ]
Feinstein, SB [1 ]
机构
[1] UNIV ILLINOIS,DEPT MED,CARDIOL SECT,CHICAGO,IL 60612
关键词
D O I
10.1016/S0894-7317(97)80029-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Albunex is an Food and Drug Administration-approved ultrasound contrast agent used for the enhancement of left ventricular endocardial borders. To determine the efficacy of intravenously administered Albunex with regard to left ventricular opacification (LVO), a retrospective analysis of 117 patients who received 202 injections of Albunex for enhancement of endocardial borders was done (dose 0.08 to 0.22 ml/kg). Patients were routinely referred to our echocardiography laboratory for stress echocardiography for standard indications. Optimized settings for contrast enhancement (3.5 MHz transducer frequency and maximum dynamic range) were used. Four observers graded LVO on a scale from 0 to 3 (0 = no Albunex seen in the ventricular cavity; 3 = Albunex densely seen in the ventricular cavity). Overall, LVO was reported in 166 (82%) of 202 injections or in 91 (78%) of 117 patients. A significant reduction in LVO was noted in patients with mitral regurgitation, tricuspid regurgitation, atrial fibrillation, systolic dysfunction, or pulmonary hypertension (increased pulmonary artery systemic pressure). LVO was seen in 88% of the patients without these conditions. However, only 12 (44%) of 27 patients with one or more of the above conditions had LVO (p < 0.05). LVO can be achieved in the majority of patients after intravenously administered Albunex when imaged with optimal transducer settings. A subset of patients with systolic dysfunction, mitral regurgitation, tricuspid regurgitation, atrial fi brillation, or increased pulmonary artery systemic pressure has less effective LVO with Albunex. Heart disease associated with decreased forward how appears to be associated with diminished LVO.
引用
收藏
页码:25 / 30
页数:6
相关论文
共 17 条
[1]   CONTRAST ECHOCARDIOGRAPHY DURING CARDIAC-CATHETERIZATION IN PATIENTS WITH CONGENITAL HEART-DISEASES [J].
ANDRADE, JL ;
LEAL, SMB ;
FILHO, OC ;
CARVALHO, AC ;
TEBEXRENI, AS ;
LIMA, VC .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 29 (02) :117-121
[2]   CHARACTERISTICS OF ALBUNEX - AIR-FILLED ALBUMIN MICROSPHERES FOR ECHOCARDIOGRAPHY CONTRAST ENHANCEMENT [J].
BARNHART, J ;
LEVENE, H ;
VILLAPANDO, E ;
MANIQUIS, J ;
FERNANDEZ, J ;
RICE, S ;
JABLONSKI, E ;
GJOEN, T ;
TOLLESHAUG, H .
INVESTIGATIVE RADIOLOGY, 1990, 25 :S162-S164
[3]  
BLOCK R, 1995, J AM SOC ECHOCARDIAG, V8, P360
[4]  
BRODSKY L, 1995, J AM SOC ECHOCARDIOG, V8, P360
[5]   OPACIFICATION AND BORDER DELINEATION IMPROVEMENT IN PATIENTS WITH SUBOPTIMAL ENDOCARDIAL BORDER DEFINITION IN ROUTINE ECHOCARDIOGRAPHY - RESULTS OF THE PHASE-III ALBUNEX MULTICENTER TRIAL [J].
CROUSE, LJ ;
CHEIRIF, J ;
HANLY, DE ;
KISSLO, JA ;
LABOVITZ, AJ ;
RAICHLEN, JS ;
SCHUTZ, RW ;
SHAH, PM ;
SMITH, MD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) :1494-1500
[6]   IDENTIFICATION OF ULTRASOUND ECHOES FROM LEFT VENTRICLE BY USE OF INTRACARDIAC INJECTIONS OF INDOCYANINE GREEN [J].
FEIGENBA.H ;
STONE, JM ;
LEE, DA ;
NASSER, WK ;
CHANG, S .
CIRCULATION, 1970, 41 (04) :615-&
[7]  
Feinstein S B, 1989, J Am Soc Echocardiogr, V2, P125
[8]   SAFETY AND EFFICACY OF A NEW TRANSPULMONARY ULTRASOUND CONTRAST AGENT - INITIAL MULTICENTER CLINICAL-RESULTS [J].
FEINSTEIN, SB ;
CHEIRIF, J ;
TENCATE, FJ ;
SILVERMAN, PR ;
HEIDENREICH, PA ;
DICK, C ;
DESIR, RM ;
ARMSTRONG, WF ;
QUINONES, MA ;
SHAH, PM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (02) :316-324
[9]   USE OF AN ULTRASONIC CONTRAST METHOD IN DIAGNOSIS OF VALVULAR REGURGITATION AND INTRACARDIAC SHUNTS [J].
KERBER, RE ;
KIOSCHOS, JM ;
LAUER, RM .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 34 (06) :722-727
[10]   TRANSIENT MYOCARDIAL CONTRAST AFTER INITIAL EXPOSURE TO DIAGNOSTIC ULTRASOUND PRESSURES WITH MINUTE DOSES OF INTRAVENOUSLY INJECTED MICROBUBBLES - DEMONSTRATION AND POTENTIAL MECHANISMS [J].
PORTER, TR ;
XIE, F .
CIRCULATION, 1995, 92 (09) :2391-2395