Repositioning accuracy of a noninvasive head fixation system for stereotactic radiotherapy

被引:36
作者
Hamilton, RJ
Kuchnir, FT
Pelizzari, CA
Sweeney, PJ
Rubin, SJ
机构
[1] University of Chicago, Dept. of Radiat. and Cell. Oncology, MC 1105, Chicago, IL 60637
[2] University of Chicago, Dept. of Radiat. and Cell. Oncology, MC 0085, Chicago, IL 60637
关键词
immobilization; localization; positioning; stereotactic radiotherapy;
D O I
10.1118/1.597754
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We report on the repositioning accuracy of patient setup achieved with a noninvasive head fixation device for stereotactic radiotherapy. A custom head mask which attaches to our stereotactic radiosurgery head ring assembly is fabricated for each patient. The position and orientation of a patient in the stereotactic space at the time of treatment are determined from analyzing portal films containing images of radio-opaque spheres embedded in a custom mouthpiece. From analysis of 104 setups of 12 patients, we find that the average distance between the treated isocenter and its mean position is 1.8 mm, and that the standard deviations of the position of the treated isocenter in stereotactic coordinate space about its mean position are less than 1.4 mm in translation in any direction and less than 1 degrees of rotation about any axis. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:1909 / 1917
页数:9
相关论文
共 32 条
[1]  
BETTI OO, 1984, ACTA NEUROCHIRURGI S, V33, P385
[2]  
BOVA FJ, COMMUNICATION
[3]  
CAROL MP, 1993, STEREOTACTIC SURG RA
[4]   FROM RADIOTHERAPY TO STEREOTAXIC RADIOSURGERY - PHYSICAL AND DOSIMETRICAL CONSIDERATIONS [J].
CHIEREGO, G ;
FRANCESCON, P ;
COLOMBO, F ;
POZZA, F .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :214-218
[5]   EXTERNAL STEREOTACTIC IRRADIATION BY LINEAR-ACCELERATOR [J].
COLOMBO, F ;
BENEDETTI, A ;
POZZA, F ;
AVANZO, RC ;
MARCHETTI, C ;
CHIEREGO, G ;
ZANARDO, A .
NEUROSURGERY, 1985, 16 (02) :154-160
[6]   FRACTIONATED RADIOTHERAPY OF SMALL INOPERABLE LESIONS OF THE BRAIN USING A NONINVASIVE STEREOTAXIC FRAME [J].
DELANNES, M ;
DALY, NJ ;
BONNET, J ;
SABATIER, J ;
TREMOULET, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (03) :749-755
[7]   FRACTIONATED STEREOTAXICALLY GUIDED RADIOTHERAPY OF HEAD AND NECK TUMORS - A REPORT ON CLINICAL USE OF A NEW SYSTEM IN 195 CASES [J].
GADEMANN, G ;
SCHLEGEL, W ;
DEBUS, J ;
SCHAD, L ;
BORTFELD, T ;
HOVER, KH ;
LORENZ, WJ ;
WANNENMACHER, M .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :205-213
[8]  
GALL KP, 1993, MED PHYS, V20, P1153, DOI 10.1118/1.596969
[9]   RELOCATABLE FRAME FOR STEREOTAXIC EXTERNAL BEAM RADIOTHERAPY [J].
GILL, SS ;
THOMAS, DGT ;
WARRINGTON, AP ;
BRADA, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03) :599-603
[10]   THE RADIOBIOLOGY OF RADIOSURGERY - RATIONALE FOR DIFFERENT TREATMENT REGIMES FOR AVMS AND MALIGNANCIES [J].
HALL, EJ ;
BRENNER, DJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (02) :381-385