A microplate solid scintillation counter as a radioactivity detector for high performance liquid chromatography in drug metabolism: Validation and applications

被引:22
作者
Bruin, Gerard J. [1 ]
Waldmeier, Felix [1 ]
Boernsen, K. Olaf [1 ]
Pfaar, Ulrike [1 ]
Gross, Gerhard [1 ]
Zollinger, Markus [1 ]
机构
[1] Novartis Pharma AG, CH-4002 Basel, Switzerland
关键词
offline HPLC radioactivity detection; microplate scintillation counter; animal and human ADME studies;
D O I
10.1016/j.chroma.2006.08.020
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Sensitive radioactivity detection following high performance liquid chromatography (HPLC) separation remains a challenge in many drug metabolism studies with radiolabeled compounds. In this work, solid scintillation counting (SSC) after fraction collection into 96-well plates was evaluated as an off-line radioactivity detection method, in comparison with conventional liquid scintillation counting (LSC). The impact of counting time and biological matrix on the quantification of radiolabeled metabolites and parent drug in samples from animal and human absorption, distribution, metabolism and excretion (ADME) studies was investigated. Three different approaches were used to test whether reliable quantification by off-line SSC detection, which requires an approximately constant counting yield during the entire chromatographic run, can be realized: (i) the measurement of radioactivity-spiked biological blank samples without HPLC separation as an extreme case of biological background, (ii) the measurement of radioactivity-spiked HPLC fractions of biological blank samples and (iii) the comparison of radiochromatograms obtained by off-line SSC and LSC of real samples from ADME studies with radiolabeled compounds. Situations in which variations in SSC yield during an HPLC run are likely to lead to significant errors in quantitation were identified and are discussed. However, examples from a number of animal or human ADME studies showed that in the majority of cases off-line SSC provides very similar quantitative data, compared with the reference method of off-line LSC radioactivity detection. Approaches for validation of the off-line SSC approach in critical cases are discussed. The main advantages of off-line SSC, compared with off-line LSC, are lower detection limits and a substantially higher throughput. Several applications of off-line SSC detection in ADME studies are shown. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 194
页数:11
相关论文
共 18 条
[1]
Determination of the specific activity of sheep plasma amino acids using high-performance liquid chromatography: comparison study between liquid scintillation counter and on-line flow-through detector [J].
Ahmed, LS ;
Moorehead, H ;
Leitch, CA ;
Liechty, EA .
JOURNAL OF CHROMATOGRAPHY B, 1998, 710 (1-2) :27-35
[2]
Use of a microplate scintillation counter as a radioactivity detector for miniaturized separation techniques in drug metabolism [J].
Boemsen, KO ;
Floeckher, JM ;
Bruin, GJM .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3956-3959
[3]
BOERNSEN KO, 2000, APPL NOTE USING TOPC
[5]
Metabolism, pharmacokinetics, and excretion of a highly selective N-methyl-D-aspartate receptor antagonist, traxoprodil, in human cytochrome P450 2D6 extensive and poor metabolizers [J].
Johnson, K ;
Shah, A ;
Jaw-Tsai, S ;
Baxter, J ;
Prakash, C .
DRUG METABOLISM AND DISPOSITION, 2003, 31 (01) :76-87
[6]
Combination of high-performance liquid chromatography and microplate scintillation counting for crop and animal metabolism studies: A comparison with classical on-line and thin-layer chromatography radioactivity detection [J].
Kiffe, M ;
Jehle, A ;
Ruembeli, R .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :723-730
[7]
LANNUNZIATA MF, 1998, HDB RADIOACTIVITY AN, P291
[8]
On-line liquid chromatography-accurate radioisotope counting coupled with a radioactivity detector and mass spectrometer for metabolite identification in drug discovery and development [J].
Nassar, AEF ;
Bjorge, SM ;
Lee, DY .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :785-790
[9]
The use of 96-well Scintiplates to facilitate definitive metabolism studies for drug candidates [J].
Nedderman, ANR ;
Savage, ME ;
White, KL ;
Walker, DK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (03) :607-617
[10]
Radiochemical detection for packed capillary liquid chromatography-mass spectrometry [J].
Onisko, BC .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (01) :82-84