Variability of the diameter and taper of size #30, 0.04 gutta-percha cones

被引:5
作者
Cunningham, Kevin P.
Walker, Mary P.
Kulild, James C.
Lask, John T.
机构
[1] Univ Missouri, Sch Dent, Dept Restorat Dent, Kansas City, MO 64108 USA
[2] Univ Missouri, Sch Dent, Dept Oral Biol, Kansas City, MO 64108 USA
[3] Univ Missouri, Sch Dent, Dept Endodont, Kansas City, MO 64108 USA
关键词
cone tip diameter; dental obturating cones; gutta-percha; taper; variability;
D O I
10.1016/j.joen.2006.06.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this investigation was to examine variability of gutta-percha (GP) cone tip diameter (D-0) and taper among five different brands of not equal 30, 0.04 GP cones (n = 15/brand). Mean percent Do difference from the manufacturer's reported (nominal) diameter of Maillefer (-15.42 +/- 7.16%) and Lexicon (-12.76 +/- 4.98%) were significantly different (p <= 0.05) from Maxima (3.18 +/- 7.06%), Diadent (3.62 +/- 11.37%), and K-3 (7.27 +/- 7.84%), which were not significantly different from each other but exhibited diameters larger than the nominal diameter as indicated by positive values. Mean taper percent difference of Maxima (-3.00 +/- 3.80%) was significantly different (p :5 0.05) from Lexicon (3.67 +/- 3.64%) and Maillefer (6.67 +/- 3.49%), with comparisons to Diadent (-0.17 +/- 6.37%) and K-3 (1.50 +/- 6.93%) not significantly different (p > 0.05) from each other or any other brand. Based on the evidence, there is significant variability between GP cone brands for both diameter and taper, with Maxima and Diadent, respectively, exhibiting the smallest mean difference from manufacturer's nominal tip diameter and taper. However, the high standard deviation values associated with most of the diameter and taper differences from nominal values also suggest high variability within individual brands.
引用
收藏
页码:1081 / 1084
页数:4
相关论文
共 20 条
[1]  
*AM NAT STAND I AM, 2000, 78 AM NAT STAND I AM
[2]  
FRIEDMAN CM, 1975, J DENT RES, V54, P921, DOI 10.1177/00220345750540052901
[3]  
GOLDBERG F, 1991, ENDOD DENT TRAUMATOL, V7, P15
[4]   MICROSCOPIC STUDY OF STANDARDIZED GUTTA-PERCHA POINTS [J].
GOLDBERG, F ;
GURFINKEL, J ;
SPIELBERG, C .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1979, 47 (03) :275-276
[5]  
GREEN E N, 1957, Oral Surg Oral Med Oral Pathol, V10, P532, DOI 10.1016/0030-4220(57)90013-0
[6]   EVALUATION OF SIZE VARIATION BETWEEN ENDODONTIC FINGER SPREADERS AND ACCESSORY GUTTA-PERCHA CONES [J].
HARTWELL, GR ;
BARBIERI, SJ ;
GERARD, SE ;
GUNSOLLEY, JC .
JOURNAL OF ENDODONTICS, 1991, 17 (01) :8-11
[7]  
INGLE J, 1958, T 2 INT C END PHIL U, V234, P123
[8]  
INGLE J I, 1961, Oral Surg Oral Med Oral Pathol, V14, P83, DOI 10.1016/0030-4220(61)90477-7
[9]  
INGLE J I, 1955, Oral Surg Oral Med Oral Pathol, V8, P1211, DOI 10.1016/0030-4220(55)90385-6
[10]  
*INT ORG STAND, 1995, 6877 ISO