Real-time monitoring of the strand displacement amplification (SDA) of human cytomegalovirus by a new SDA-piezoelectric DNA sensor system

被引:19
作者
Chen, Qinghai [1 ]
Bian, Zhihen [1 ]
Chen, Ming [1 ]
Hua, Xing [1 ]
Yao, Chunyan [1 ]
Xia, Han [1 ]
Kuang, Hong [1 ]
Zhang, Xue [1 ]
Huang, Junfu [1 ]
Cai, Guoru [2 ]
Fu, Weiling [1 ]
机构
[1] Third Mil Med Univ, SW Hosp, Ctr Mol & Gene Diag, Chongqing 400038, Peoples R China
[2] Natl Informat Ind Dept, Elect Res Inst 26, Chongqing 400060, Peoples R China
关键词
Piezoelectric sensor; Strand displacement amplification (SDA); Dynamic real-time monitoring; Human cytomegalovirus (HCMV); NUCLEIC-ACID AMPLIFICATION; SELF-ASSEMBLED MONOLAYER; QUARTZ-CRYSTAL; MICROBALANCE SENSORS;
D O I
10.1016/j.bios.2009.06.012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Nucleic acid amplification has long been used in biosensor technologies, such as DNA sensors, DNA chips and microarrays, due to its advantage of high sensitivity in detecting target DNA. However, dynamic monitoring of nucleic acid amplifications with traditional DNA sensors in real-time is difficult since a constant temperature must be maintained during detection. Thus, the piezoelectric sensor, one type of traditional DNA sensor, is not applicable in real-time monitoring PCR due to the dramatic change in temperature that occurs during reaction. In this study, we introduced strand displacement amplification (SDA), an well-developed nucleic acid amplification technique that can work under conditions of constant temperature, into the development of a novel piezoelectric sensor. Using the new SDA-piezoelectric DNA sensor, we designed a stable system for liquid-phase detection, in which the crystal oscillator plate was fixed by an easily adjustable screw-threaded clamping mechanism and successfully applied the new sensor system to real-time SDA monitoring of human cytomegalovirus (HCMV). This new technique overcomes the shortcomings of traditional DNA sensors in real-time monitoring of nucleic acid amplification. The technique has proved to be a markedly simplified procedure with a number of advantages, such as higher sensitivity, better time efficiency, and the ability of dynamic real-time detection. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3412 / 3418
页数:7
相关论文
共 34 条
[1]   Monitoring the real time growth of a self-assembled monolayer on a polymer electrolyte surface [J].
Carlisle, Justin ;
Layson, Anthony .
ELECTROCHIMICA ACTA, 2007, 53 (04) :1628-1634
[2]   The principle and applications of piezoelectric crystal sensors [J].
Chang, SM ;
Muramatsu, H ;
Nakamura, C ;
Miyake, J .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2000, 12 (1-2) :111-123
[3]   Characterization of aspartate transcarbamylase activity from gonads of the soft shell clam, Mya arenaria [J].
Etchian, OA ;
Pellerin, J .
COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY B-BIOCHEMISTRY & MOLECULAR BIOLOGY, 2003, 134 (04) :615-629
[4]  
Ginocchio C. C., 2004, Clinical Microbiology Newsletter, V26, P129, DOI 10.1016/j.clinmicnews.2004.08.002
[5]   Human cytomegalovirus gene expression during infection of primary hematopoietic progenitor cells: A model for latency [J].
Goodrum, FD ;
Jordan, CT ;
High, K ;
Shenk, T .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (25) :16255-16260
[6]  
HEGDE NR, 2005, J CELL BIOL, V171, P1109
[7]  
ITAMAR W, 2001, TRENDS BIOTECHNOL, V196, P222
[8]   Crystallization and preliminary X-ray characterization of two thermostable DNA nucleases [J].
Kuettner, E. Bartholomeus ;
Pfeifer, Sven ;
Keim, Antje ;
Greiner-Stoeffele, Thomas ;
Straeter, Norbert .
ACTA CRYSTALLOGRAPHICA SECTION F-STRUCTURAL BIOLOGY COMMUNICATIONS, 2006, 62 :1290-1293
[9]   Whole genome analysis of genetic alterations in small DNA samples using hyperbranched strand displacement amplification and array-CGH [J].
Lage, JM ;
Leamon, JH ;
Pejovic, T ;
Hamann, S ;
Lacey, M ;
Dillon, D ;
Segraves, R ;
Vossbrinck, B ;
González, A ;
Pinkel, D ;
Albertson, DG ;
Costa, J ;
Lizardi, PM .
GENOME RESEARCH, 2003, 13 (02) :294-307
[10]   Rapid, sequence-specific detection of unpurified PCR amplicons via a reusable, electrochemical sensor [J].
Lai, RY ;
Lagally, ET ;
Lee, SH ;
Soh, HT ;
Plaxco, KW ;
Heeger, AJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (11) :4017-4021