Computerized equipment for the delivery of inhaled doses of solid particles in specific bronchial challenge

被引:21
作者
Fabriès, JF [1 ]
Choudat, D [1 ]
Wrobel, R [1 ]
Cloutier, Y [1 ]
Dessanges, JF [1 ]
Villette, C [1 ]
Ava, JD [1 ]
Conso, F [1 ]
机构
[1] Inst Natl Rech & Secur, F-54501 Vandoeuvre Les Nancy, France
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 2000年 / 13卷 / 01期
关键词
specific bronchial challenge; inhaled dose; occupational asthma; aerosol concentration; particle size;
D O I
10.1089/jam.2000.13.1
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 [公共卫生与预防医学]; 120402 [社会医学与卫生事业管理];
摘要
An apparatus to generate solid particles was tested for use in diagnosing occupational asthma. This equipment measures the inhaled dose of dry particles during specific inhalation challenge. It includes an aerosol generator, a cyclone type particle size selector, and an inhalation chamber to which a patient breathing at tidal volume can be connected for the test. It is fully controlled by a standard personal computer in automatic mode, acting on the flow rate and the aerosol generator to maintain the concentration at a fixed value, usually 3 mg/m(3). The dose of aerosol delivered to the patient was calculated from the aerosol concentration, and the inhaled volume was calculated by integration of the corresponding signals. The coefficient of variation for this measurement was estimated to be 12%. The mass median aerodynamic diameter (MMAD) of aerosol inside the inhalation chamber was measured for three substances: lactose, wheat flour, and buckwheat flour. The MMAD of the aerosol inside the chamber was also estimated from the particle size distribution of the raw powder. The relative difference between the measured MMAD and the calculated value was less than 15%. The corresponding relative difference between the measured geometrical SD and the calculated value was found to be less than 26%.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 25 条
[1]
AMEILLE J, 1996, ARCH MAL PROF, V57, P75
[2]
BARON PA, 1993, AEROSOL MEASUREMENT, P381
[3]
BOHADANA AB, 1994, EUR RESPIR J, V7, P1070
[4]
Carletti A M, 1997, Med Lav, V88, P406
[5]
Cartier Andre, 1993, P215
[6]
Choudat D, 1999, EUR RESPIR J, V14, P328
[7]
CLOUTIER Y, 1992, EUR RESPIR J, V5, P887
[8]
CLOUTIER Y, 1989, EUR RESPIR J, V2, P769
[9]
VALIDATION OF AN EXPOSURE SYSTEM TO PARTICLES FOR THE DIAGNOSIS OF OCCUPATIONAL ASTHMA [J].
CLOUTIER, Y ;
LAGIER, F ;
CARTIER, A ;
MALO, JL .
CHEST, 1992, 102 (02) :402-407
[10]
OCCUPATIONAL RESPIRATORY-DISEASES IN BRITISH-COLUMBIA, CANADA IN 1991 [J].
CONTRERAS, GR ;
ROUSSEAU, R ;
CHANYEUNG, M .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1994, 51 (10) :710-712