Should Dialysis Modalities be Designed to Remove Specific Uremic Toxins?

被引:9
作者
Baurmeister, Ulrich [3 ]
Vienken, Joerg [2 ]
Ward, Richard A. [1 ]
机构
[1] Univ Louisville, Kidney Dis Program, Louisville, KY 40202 USA
[2] Fresenius Med Care, Bad Homburg, Germany
[3] MedTec Consultants, Wuppertal, Germany
关键词
ACUTE-RENAL-FAILURE; MEMBRANE-PERMEABILITY; HEMODIALYSIS-PATIENTS; SEPTIC PATIENTS; MORTALITY RISK; FLUX; CUTOFF; HEMOFILTRATION; TRIAL;
D O I
10.1111/j.1525-139X.2009.00599.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
100201 [内科学]; 100221 [泌尿外科学];
摘要
The definition of optimal dialysis therapy remains elusive. Randomized clinical trials have neither supported using urea as a surrogate marker for uremic toxicity nor provided clear cut evidence in favor of larger solutes. Thus, where to focus resources in the development of new membranes, and therapies remains unclear. Three basic questions remain unanswered: (i) what solute(s) should be used as a marker for optimal dialysis; (ii) should dialytic therapies be designed to remove a specific solute; and (iii) how can current therapies be modified to provide better control of uremic toxicity? Identification of a single, well-defined uremic toxin appears to be unlikely as new analytical tools reveal an increasingly complex uremic milieu. As a result, it is probable that membranes and therapies should be designed for the nonspecific removal of a wide variety of solutes retained in uremia. Removal of the widest range of solutes can best be achieved using existing therapies that incorporate convection in conjunction with longer treatment times and more frequent treatments. Membranes capable of removing solutes over an expanded effective molecular size range can already be fabricated; however, their use will require novel approaches to conserve proteins, such as albumin.
引用
收藏
页码:454 / 457
页数:4
相关论文
共 25 条
[1]
Mortality risk for patients receiving hemodiafiltration versus hemodialysis: European results from the DOPPS [J].
Canaud, B. ;
Bragg-Gresham, J. L. ;
Marshall, M. R. ;
Desmeules, S. ;
Gillespie, B. W. ;
Depner, T. ;
Klassen, P. ;
Port, F. K. .
KIDNEY INTERNATIONAL, 2006, 69 (11) :2087-2093
[2]
Serum β-2 microglobulin levels predict mortality in dialysis patients:: Results of the HEMO study [J].
Cheung, Alfred K. ;
Rocco, Michael V. ;
Yan, Guofen ;
Leypoldt, John K. ;
Levin, Nathan W. ;
Greene, Tom ;
Agodoa, Lawrence ;
Bailey, James ;
Beck, Gerald J. ;
Clark, William ;
Levey, Andrew S. ;
Ornt, Daniel B. ;
Schulman, Gerald ;
Schwab, Steven ;
Teehan, Brendan ;
Eknoyan, Garabed .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 17 (02) :546-555
[3]
Enhanced clearance of highly protein-bound drugs by albumin-supplemented dialysate during modeled continuous hemodialysis [J].
Churchwell, Mariann D. ;
Pasko, Deborah A. ;
Smoyer, William E. ;
Mueller, Bruce A. .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2009, 24 (01) :231-238
[4]
Effect of the super-flux cellulose triacetate dialyser membrane on the removal of non-protein-bound and protein-bound uraemic solutes [J].
De Smet, Rita ;
Dhondt, Annemieke ;
Eloot, Sunny ;
Galli, Francesco ;
Waterloos, Marie Anne ;
Vanholder, Raymond .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (07) :2006-2012
[5]
*EBPG EXP GROUP HA, 2002, NEPHROL DIAL TRAN S7, V17, P21
[6]
Effect of dialysis dose and membrane flux in maintenance hemodialysis. [J].
Eknoyan, G ;
Beck, GJ ;
Cheung, AK ;
Daugirdas, JT ;
Greene, T ;
Kusek, JW ;
Allon, M ;
Bailey, J ;
Delmez, JA ;
Depner, TA ;
Dwyer, JT ;
Levey, AS ;
Levin, NW ;
Milford, E ;
Ornt, DB ;
Rocco, MV ;
Schulman, G ;
Schwab, SJ ;
Teehan, BP ;
Toto, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (25) :2010-2019
[7]
Hemodialysis membrane with a high-molecular-weight cutoff and cytokine levels in sepsis complicated by acute renal failure: A phase 1 randomized trial [J].
Haase, Michael ;
Bellomo, Rinaldo ;
Baldwin, Ian ;
Haase-Fielitz, Anja ;
Fealy, Nigel ;
Davenport, Piers ;
Morgera, Stanislao ;
Goehl, Hermann ;
Storr, Markus ;
Boyce, Neil ;
Neumayer, Hans-Hellmut .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2007, 50 (02) :296-304
[8]
HORNBERGER JC, 1992, J AM SOC NEPHROL, V3, P1227
[9]
Efficient removal of immunoglobulin free light chains by hemodialysis for multiple myeloma:: In vitro and in vivo studies [J].
Hutchison, Colin A. ;
Cockwell, Paul ;
Reid, Steven ;
Chandler, Katie ;
Mead, Graham P. ;
Harrison, John ;
Hattersley, John ;
Evans, Neil D. ;
Chappell, Mike J. ;
Cook, Mark ;
Goehl, Hermann ;
Storr, Markus ;
Bradwell, Arthur R. .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2007, 18 (03) :886-895
[10]
Serum Free-Light Chain Removal by High Cutoff Hemodialysis: Optimizing Removal and Supportive Care [J].
Hutchison, Colin A. ;
Harding, Stephen ;
Mead, Graham ;
Goehl, Hermann ;
Storr, Markus ;
Bradwell, Arthur ;
Cockwell, Paul .
ARTIFICIAL ORGANS, 2008, 32 (12) :910-917