Microchip capillary electrophoresis with electrochemical detection

被引:87
作者
Zeng, Y [1 ]
Chen, H [1 ]
Pang, DW [1 ]
Wang, ZL [1 ]
Cheng, JK [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
D O I
10.1021/ac0110247
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel microchip capillary electrophoresis system with electrochemical detection, using the replaceable microelectrode, is first reported. This kind of electrode can be fabricated in general laboratories and can be replaced quickly with electrodes of different materials according to the requirements of experiments. The end-column electrochemical detection on microchip CE was achieved by fixing the working electrode (such as carbon fiber, Pt, or An, etc.) through a guide tube on the end of the separation channel. The experiment results indicate that the alignment of the electrode with the channel outlet can be carried out accurately and reproducibly, and therefore, the detection device has low noise and good reproducibility. The detection limit of dopamine is 2.4 x 10(-7) M, which is the lowest result reported so far. The separation and detection of dopamine, 5-hydroxytryptamine and epinephrine using carbon fiber and Pt microdisk electrodes within 50 s was successfully performed.
引用
收藏
页码:2441 / 2445
页数:5
相关论文
共 42 条
[1]  
Becker H, 2000, ELECTROPHORESIS, V21, P12, DOI 10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.0.CO
[2]  
2-7
[3]  
Bruin GJM, 2000, ELECTROPHORESIS, V21, P3931, DOI 10.1002/1522-2683(200012)21:18<3931::AID-ELPS3931>3.0.CO
[4]  
2-M
[5]   Palladium film decoupler for amperometric detection in electrophoresis chips [J].
Chen, DC ;
Hsu, FL ;
Zhan, DZ ;
Chen, CH .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :758-762
[6]   CAPILLARY ELECTROPHORESIS WITH AMPEROMETRIC DETECTION USING A POROUS CELLULOSE-ACETATE JOINT [J].
CHEN, IC ;
WHANG, CW .
JOURNAL OF CHROMATOGRAPHY, 1993, 644 (01) :208-212
[7]   AN ELECTROCHEMICAL COIL FOR END-COLUMN AMPEROMETRIC DETECTION IN CAPILLARY ELECTROPHORESIS [J].
CHEN, MC ;
HUANG, HJ .
ANALYTICAL CHEMISTRY, 1995, 67 (21) :4010-4014
[8]   Electroosmotically induced hydraulic pumping on microchips: Differential ion transport [J].
Culbertson, CT ;
Ramsey, RS ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2000, 72 (10) :2285-2291
[9]   FARADAIC ELECTROCHEMISTRY AT MICRO-VOLTAMMETRIC ELECTRODES [J].
DAYTON, MA ;
BROWN, JC ;
STUTTS, KJ ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1980, 52 (06) :946-950
[10]  
Dolník V, 2000, ELECTROPHORESIS, V21, P41, DOI 10.1002/(SICI)1522-2683(20000101)21:1<41::AID-ELPS41>3.0.CO