Method development and validation for quantitative determination of methadone enantiomers in human plasma by liquid chromatography/tandem mass spectrometry

被引:53
作者
Liang, HR [1 ]
Foltz, RL [1 ]
Meng, M [1 ]
Bennett, P [1 ]
机构
[1] NWT Inc, Div A, Tandem Labs, Salt Lake City, UT 84124 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2004年 / 806卷 / 02期
关键词
enantiomer separation; methadone;
D O I
10.1016/j.jchromb.2004.03.059
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-throughput method for quantitative determination of methadone enantiomers in human plasma was developed and validated by liquid chromatography/tandem mass spectrometry. The effects of pH and of types and concentrations of mobile-phase modifiers on the enantioselectivity of (R)- and (S)-methadone were investigated on a Chiral-AGP column. A baseline separation of the enantiomers was achieved with a retention time of less than 5 min. Ionization suppression and other matrix effects were evaluated. Morphine, cocaine, 6-monoacetylmorphine, benzoylecgonine and ecgonine methyl ester did not interfere with the performance of the assay. The specificity, linearity, intra- and inter-assay precision and accuracy, and extraction recovery were fully evaluated. The method showed excellent reproducibility (overall coefficient of variance < 8%) and accuracy (overall bias < 2.7%) with a broad linear range. The enantiomers were stable in human plasma after five freeze-thaw cycles, under bench-top storage at room temperature (RT) for 6 h, in the extract reconstitution solution at RT for 17 h, and in processed-extracts stored at RT for 142 h. This validated LC/MS/MS assay offers high-throughput and improved specificity, sensitivity, linear range and ruggedness over previously published methods and has been successfully applied to the analysis of clinical samples. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 36 条
[1]   RETENTION PROCESSES ON ALPHA-1-ACID GLYCOPROTEIN-BONDED STATIONARY PHASE [J].
ARVIDSSON, E ;
JANSSON, SO ;
SCHILL, G .
JOURNAL OF CHROMATOGRAPHY, 1992, 591 (1-2) :55-63
[2]  
Bakhtiar R, 2000, RAPID COMMUN MASS SP, V14, P1128, DOI 10.1002/1097-0231(20000715)14:13<1128::AID-RCM1>3.0.CO
[3]  
2-5
[4]   CHIRAL ANALYSIS OF METHADONE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BECK, O ;
BOREUS, LO ;
LAFOLIE, P ;
JACOBSSON, G .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (01) :198-202
[5]  
Casy AF, 1986, OPIOID ANALGESICS CH
[6]  
Cherkaoui S, 2001, ELECTROPHORESIS, V22, P3308, DOI 10.1002/1522-2683(200109)22:15<3308::AID-ELPS3308>3.0.CO
[7]  
2-H
[8]   INFLUENCE OF UNCHARGED MOBILE PHASE ADDITIVES ON RETENTION AND ENANTIOSELECTIVITY OF CHIRAL DRUGS USING AN ALPHA-1-ACID GLYCOPROTEIN COLUMN [J].
ENQUIST, M ;
HERMANSSON, J .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (02) :271-283
[9]   Stereoselective quantification of methadone and its major oxidative metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, in human urine using high-performance liquid chromatography [J].
Foster, DJR ;
Somogyi, AA ;
Bochner, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 744 (01) :165-176
[10]   OPTIMIZATION OF THE SEPARATION OF ENANTIOMERS OF BASIC DRUGS - RETENTION MECHANISMS AND DYNAMIC MODIFICATION OF THE CHIRAL BONDING PROPERTIES ON AN ALPHA(1)-ACID GLYCOPROTEIN COLUMN [J].
HERMANSSON, J ;
GRAHN, A .
JOURNAL OF CHROMATOGRAPHY A, 1995, 694 (01) :57-69