Studies of lead tungstate crystal matrices in high energy beams for the CMS electromagnetic calorimeter at the LHC

被引:13
作者
Alexeev, G
Auffray, E
Baillon, P
Barney, D
Bassompierre, G
Bateman, E
Bell, KW
Benhammou, Y
Bloch, P
Bomestar, D
Borgia, B
Bourotte, J
Burge, S
Cameron, W
Chipaux, R
Cockerill, D
Connolly, J
Dafinei, I
Denes, P
Depasse, P
Deiters, K
Dobrzynski, L
ElMamouni, H
Faure, JL
Felcini, M
Finger, M
Flugel, T
Gautheron, F
Givernaud, A
Gninenko, S
Godinovic, N
Graham, DJ
Guillaud, JP
Guschin, E
Haguenauer, M
Hillemanns, H
Hofer, H
Ille, B
Jaaskelainen, S
Katchanov, V
Kennedy, B
Kirn, T
Korzhik, M
LassilaPerini, K
Lebeau, M
Lebrun, P
Lecoq, P
Lecoeur, G
Lecomte, P
Leonardi, E
机构
[1] UNIV LONDON IMPERIAL COLL SCI TECHNOL & MED, LONDON, ENGLAND
[2] RHEIN WESTFAL TH AACHEN, AACHEN, GERMANY
[3] LAPP, ANNECY, FRANCE
[4] UNIV BRISTOL, BRISTOL, AVON, ENGLAND
[5] RUTHERFORD APPLETON LAB, DIDCOT OX11 0QX, OXON, ENGLAND
[6] CERN, GENEVA, SWITZERLAND
[7] SACLAY, GIF SUR YVETTE, FRANCE
[8] LAWRENCE LIVERMORE NATL LAB, LIVERMORE, CA USA
[9] UNIV MINNESOTA, MINNEAPOLIS, MN 55455 USA
[10] INST NUCL PROBLEMS, MINSK, BELARUS
[11] INR, MOSCOW, RUSSIA
[12] ECOLE POLYTECH, LPNHE, PALAISEAU, FRANCE
[13] CALTECH, PASADENA, CA 91125 USA
[14] CHARLES UNIV, PRAGUE, CZECH REPUBLIC
[15] IHEP, PROTVINO, RUSSIA
[16] PRINCETON UNIV, PRINCETON, NJ 08544 USA
[17] UNIV ROMA LA SAPIENZA, ROME, ITALY
[18] TECH UNIV SPLIT, SPLIT, CROATIA
[19] IPN LYON, IN2P3, CNRS, VILLEURBANNE, FRANCE
[20] UNIV LYON 1, F-69622 VILLEURBANNE, FRANCE
[21] PAUL SCHERRER INST, VILLIGEN, SWITZERLAND
[22] ETH ZURICH, ZURICH, SWITZERLAND
关键词
lead tungstate; crystal; CMS; ECAL; electromagnetic calorimeter; energy resolution; APD;
D O I
10.1016/S0168-9002(96)01030-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Using matrices of lead tungstate crystals, energy resolutions better than 0.6% at 100 GeV have been achieved in the test beam in 1995. It has been demonstrated that a lead tungstate electromagnetic calorimeter read out by avalanche photodiodes can consistently achieve the excellent energy resolutions necessary to justify its construction in the CMS detector. The performance achieved has been understood in terms of the properties of the crystals and photodetectors.
引用
收藏
页码:425 / 434
页数:10
相关论文
共 3 条
[1]  
*CMS, 1994, 9438 CMS CERN LHCC
[2]   Slow components in the photoluminescence and scintillation decays of PbWO4 single crystals [J].
Nikl, M ;
Nitsch, K ;
Polak, K ;
Mihokova, E ;
Dafinei, I ;
Auffray, E ;
Lecoq, P ;
Reiche, P ;
Uecker, R ;
Pazzi, GP .
PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 1996, 195 (01) :311-323
[3]   Results from tests on matrices of lead tungstate crystals using high energy beams [J].
Peigneux, JP ;
Schneegans, M ;
Bateman, E ;
Burge, S ;
Cockerill, D ;
Connolly, J ;
Smith, B ;
Stephenson, R ;
Auffray, E ;
Barney, D ;
Dafinei, I ;
Lecoq, P ;
Virdee, TS ;
Faure, JL ;
Givernaud, A ;
Locci, E ;
Verrecchia, P ;
Barney, J ;
Cameron, W ;
Clark, D ;
Miller, D ;
Seez, C ;
Williams, M ;
Rusack, R ;
Bourotte, J ;
Haguenauer, M ;
Korzhik, M ;
Alexeev, G ;
Katchanov, V ;
Oukhanov, M ;
Shagin, P ;
Singovsky, A ;
Denes, P ;
Fluegel, T ;
Renker, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 378 (03) :410-426