Dynamic intravenous coronary arteriography using synchrotron radiation and its application to the measurement of coronary blood flow

被引:9
作者
Ohtsuka, S
Sugishita, Y
Takeda, T
Itai, Y
Hyodo, K
Ando, M
机构
[1] UNIV TSUKUBA,INST CLIN MED,DEPT CARDIOL,TSUKUBA,IBARAKI 305,JAPAN
[2] UNIV TSUKUBA,INST CLIN MED,DEPT RADIOL,TSUKUBA,IBARAKI 305,JAPAN
[3] NATL LAB HIGH ENERGY PHYS,TSUKUBA,IBARAKI 305,JAPAN
来源
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION | 1997年 / 61卷 / 05期
关键词
synchrotron radiation; intravenous coronary arteriography; coronary blood flow measurement;
D O I
10.1253/jcj.61.432
中图分类号
N09 [自然科学史]; B [哲学、宗教];
学科分类号
01 ; 0101 ; 010108 ; 060207 ; 060305 ; 0712 ;
摘要
We have developed dynamic intravenous coronary arteriography (IVCAG) using a monochromatic (33.3 keV), 2-dimensional X-ray beam (70 x 70 mm) generated from synchrotron radiation. To investigate its use to visualize the coronary arteries and to estimate coronary blood flow, we performed IVCAG in 10 dogs and 1 goat. The animals were irradiated with the synchrotron beam after intravenous injection of a contrast agent, and images were obtained using a TV camera and videorecorder. In the dogs, blood flow in the left anterior descending coronary artery (LAD) was also estimated from the images by applying a transit-time analysis. We obtained dynamic IVCAG images in the dogs and goat and could visualize even a deliberately created coronary stenosis about 1 mm in length. In addition, coronary blood flow could be estimated with an acceptable degree of accuracy. LAD flow calculated from IVCAG was 14.7+/-5.1 ml/min, whereas measured LAD flow was 16.6+/-4.8 ml/min. There was a close correlation between the estimated and measured LAD flows (r=0.90, p<0.01). Thus, dynamic IVCAG is minimally invasive, permits the simultaneous evaluation of coronary anatomy and blood flow, and may be feasible for clinical application.
引用
收藏
页码:432 / 440
页数:9
相关论文
共 25 条
[1]   AN ATTEMPT AT CORONARY ANGIOGRAPHY WITH A LARGE SIZE MONOCHROMATIC SR BEAM [J].
AKISADA, A ;
ANDO, M ;
HYODO, K ;
HASEGAWA, S ;
KONISHI, K ;
NISHIMURA, K ;
MARUHASHI, A ;
TOYOFUKU, F ;
SUWA, A ;
KOHRA, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :713-718
[2]  
BLACKWELL GG, 1995, AM J CARDIOL, V75, pD74
[3]   ACUTE REACTIONS TO INTRAVASCULAR CONTRAST-MEDIA - TYPES, RISK-FACTORS, RECOGNITION, AND SPECIFIC TREATMENT [J].
BUSH, WH ;
SWANSON, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (06) :1153-1161
[4]   MEASUREMENT OF ABSOLUTE EPICARDIAL CORONARY-ARTERY FLOW AND FLOW RESERVE WITH BREATH-HOLD CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING [J].
CLARKE, GD ;
ECKELS, R ;
CHANEY, C ;
SMITH, D ;
DITTRICH, J ;
HUNDLEY, WG ;
NESSAIVER, M ;
LI, HF ;
PARKEY, RW ;
PESHOCK, RM .
CIRCULATION, 1995, 91 (10) :2627-2634
[5]   DEDICATED X-RAY SCINTILLATION DETECTOR FOR DIGITAL SUBTRACTION ANGIOGRAPHY USING SYNCHROTRON RADIATION [J].
DEMENTIEV, EN ;
DOLBNYA, IP ;
ZAGORODNIKOV, EI ;
KOLESNIKOV, KA ;
KULIPANOV, GN ;
KURYLO, SG ;
MEDVEDKO, AS ;
MEZENTSEV, NA ;
PINDYURIN, VF ;
CHESKIDOV, VG ;
SHEROMOV, MA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :2264-2267
[6]   CORONARY ANGIOGRAPHY USING SYNCHROTRON RADIATION - STUDIES IN HUMAN-SUBJECTS WITH THE SYSTEM NIKOS-II [J].
DIX, WR ;
ENGELKE, K ;
GRAEFF, W ;
HAMM, C ;
HEUER, J ;
KAEMPF, B ;
KUPPER, W ;
LOHMANN, M ;
REIME, B ;
REUMANN, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 314 (02) :307-315
[7]  
DIX WR, 1989, REV SCI INSTRUM, V60, P2238
[8]  
HYODO K, 1991, HDB SYNCHROTRON RAD, V4, P55
[9]  
ISAKANDRIAN AS, 1995, AM J CARDIOL, V75, pD14
[10]   DICHROMATIC ABSORPTION RADIOGRAPHY - DICHROMOGRAPHY [J].
JACOBSON, B .
ACTA RADIOLOGICA, 1953, 39 (06) :437-452