Kinetic determination of cysteine on flow injection system by utilizing catalytic complexation reaction of Cu(II) with 5,10,15,20-tetrakis (4-N-trimethylammino-phenyl) porphyrin

被引:19
作者
Liu, Jianhua [1 ]
Itoh, Jun-ichi [1 ]
机构
[1] Kitami Inst Technol, Dept Appl & Environm Chem, Kitami, Hokkaido 0908507, Japan
关键词
porphyrin; flow injection analysis; kinetic method; cysteine;
D O I
10.1016/j.talanta.2006.01.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A kinetic method for the determination of cysteine on flow injection system is described. Cysteine was found as a catalyst for the complexation reaction of Cu(II) with an ultra sensitive colorimetric reagent of 5,10,15,20-tettakis (4-N-trimethylammino-phenyl) porphyrin (TTMAPP) (epsilon = 4.8 x 10(5) cm(-1) M-1 at 433 nm), which was used as the indicator reaction in this paper. Soret band of either the porphyrin or the produced complex (epsilon = 4.6 x 10(5) cm(-1) M-1 at 411 nm) can be used for detection. The continuous flow injection system greatly enhanced the analytic precision and efficiency of the kinetic method, giving a relative standard deviation of 0.73% for a 0. 1 mu g ml(-1) cysteine with 10 injections at a throughput of 30 h(-1). The detection limits (3S/N) in this case was 15 ng ml(-1) and the working dynamic range was over 25 ng ml(-1) to 1 mu g ml(-1). Sugars, organic acids and amino acids that are possible in coexistence with cysteine could be tolerated at high concentrations. This method was critically compared with the Ellman's reagent in the determinations of cysteine contents of three pharmaceutical injections for hepatic diseases and one permanent wave agent and showed better applicability in the respect of matrix interferences. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:791 / 796
页数:6
相关论文
共 29 条
[1]   Spectrophotometric determination of cysteine and N-acetylcysteine in pharmaceutical preparations [J].
Abu Eid, M .
MIKROCHIMICA ACTA, 1998, 129 (1-2) :91-95
[2]  
Al-Ghannam S. M., 2004, Farmaco (Lausanne), V59, P331, DOI 10.1016/j.farmac.2003.12.004
[3]   Specific determination of cysteine and penicillamine through cyclization to 2-thioxothiazolidine-4-carboxylic acids [J].
Amarnath, V ;
Amarnath, K .
TALANTA, 2002, 56 (04) :745-751
[4]   Kinetics of the catalytic oxidation reactions of thiol compounds in aqueous solutions in the presence of copper ions [J].
Bagiyan, GA ;
Koroleva, IK ;
Soroka, NV ;
Ufimtsev, AV .
KINETICS AND CATALYSIS, 2004, 45 (03) :372-380
[5]   Porphyrins in analytical chemistry. A review [J].
Biesaga, M ;
Pyrzynska, K ;
Trojanowicz, M .
TALANTA, 2000, 51 (02) :209-224
[6]   Kinetic method for the determination of trace amounts of copper(II) in water matrices by its catalytic effect on the oxidation of 1,5-diphenylcarbazide [J].
Crespo, GA ;
Andrade, FJ ;
Iñón, FA ;
Tudino, MB .
ANALYTICA CHIMICA ACTA, 2005, 539 (1-2) :317-325
[7]   TISSUE SULFHYDRYL GROUPS [J].
ELLMAN, GL .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1959, 82 (01) :70-77
[8]   THE DETECTION OF A TYPE OF REACTION INTERMEDIATE IN THE COMBINATION OF METAL IONS WITH PORPHYRINS [J].
FLEISCHER, EB ;
WANG, JH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1960, 82 (14) :3498-3502
[9]   Flow injection kinetic spectrophotometric determination of trace amounts of Se(IV) in seawater [J].
Gong, ZJ ;
Zhang, XS ;
Chen, GH ;
Xiao, XF .
TALANTA, 2005, 66 (04) :1012-1017