High-Density Microcavity Array for Cell Detection: Single-Cell Analysis of Hematopoietic Stem Cells in Peripheral Blood Mononuclear Cells

被引:68
作者
Hosokawa, Masahito [1 ]
Arakaki, Atsushi [1 ]
Takahashi, Masayuki [1 ]
Mori, Tetsushi [1 ]
Takeyama, Haruko [1 ]
Matsunaga, Tadashi [1 ]
机构
[1] Tokyo Univ Agr & Technol, Dept Biotechnol, Koganei, Tokyo 1848588, Japan
关键词
IDENTIFICATION; ENUMERATION; ENGRAFTMENT; MARROW; CANCER;
D O I
10.1021/ac900535h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Detection and isolation of specific cell types from limited biological samples have become a major challenge in clinical diagnosis and cell biology research. Here, we report a high-density microcavity array for target cell detection in which thousands of single cells were neatly arrayed onto 10000 microcavities with high efficiency at approximately 90% of the loaded cells. Cell-specific immunophenotypes were exclusively identified at the single-cell level by measuring fluorescence intensities of cells labeled with antibodies targeting cell surface markers, and the purity of hematopoietic stem cells (HSCs) within human peripheral blood analyzed by this system was correlated with those obtained by conventional flow cytometry. Furthermore, gene expression of the stem cell marker, CD34, was determined from HSCs by isolating single cells using a micromanipulator. This technology has proven to be an effective tool for target cell detection and subsequent cellular analytical research at the single-cell level.
引用
收藏
页码:5308 / 5313
页数:6
相关论文
共 33 条
[1]   Highly efficient circulating tumor cell isolation from whole blood and label-free enumeration using polymer-based microfluidics with an integrated conductivity sensor [J].
Adams, Andre A. ;
Okagbare, Paul I. ;
Feng, Juan ;
Hupert, Matuesz L. ;
Patterson, Don ;
Goettert, Jost ;
McCarley, Robin L. ;
Nikitopoulos, Dimitris ;
Murphy, Michael C. ;
Soper, Steven A. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (27) :8633-8641
[2]   Technical aspects and clinical impact of hematopoietic progenitor subset quantification [J].
Baech, J ;
Johnsen, HE .
STEM CELLS, 2000, 18 (02) :76-86
[3]  
BERENSON RJ, 1991, BLOOD, V77, P1717
[4]   Optical Imaging fiber-based single live cell arrays: A high-density cell assay platform [J].
Biran, I ;
Walt, DR .
ANALYTICAL CHEMISTRY, 2002, 74 (13) :3046-3054
[5]   Automatic identification of subcellular phenotypes on human cell arrays [J].
Conrad, C ;
Erfle, H ;
Warnat, P ;
Daigle, N ;
Lörch, T ;
Ellenberg, J ;
Pepperkok, R ;
Eils, R .
GENOME RESEARCH, 2004, 14 (06) :1130-1136
[6]   Dynamic single cell culture array [J].
Di Carlo, Dino ;
Wu, Liz Y. ;
Lee, Luke P. .
LAB ON A CHIP, 2006, 6 (11) :1445-1449
[7]   Single-cell enzyme concentrations, kinetics, and inhibition analysis using high-density hydrodynamic cell isolation arrays [J].
Di Carlo, Dino ;
Aghdam, Nima ;
Lee, Luke P. .
ANALYTICAL CHEMISTRY, 2006, 78 (14) :4925-4930
[8]   Microfluidic platform for real-time signaling analysis of multiple single T cells in parallel [J].
Faley, Shannon ;
Seale, Kevin ;
Hughey, Jacob ;
Schaffer, David K. ;
VanCornpernolle, Scott ;
McKinney, Brett ;
Baudenbacher, Franz ;
Unutmaz, Derya ;
Wikswo, John P. .
LAB ON A CHIP, 2008, 8 (10) :1700-1712
[9]   Electronic sorting and recovery of single live cells from microlitre sized samples [J].
Fuchs, AB ;
Romani, A ;
Freida, D ;
Medoro, G ;
Abonnenc, M ;
Altomare, L ;
Chartier, I ;
Guergour, D ;
Villiers, C ;
Marche, PN ;
Tartagni, M ;
Guerrieri, R ;
Chatelain, F ;
Manaresi, N .
LAB ON A CHIP, 2006, 6 (01) :121-126
[10]  
Gratama JW, 1998, CYTOMETRY, V34, P128, DOI 10.1002/(SICI)1097-0320(19980615)34:3<128::AID-CYTO3>3.0.CO