A statistical overview of standard (IUPAC and ACS) and new procedures for determining the limits of detection and quantification: Application to voltammetric and stripping techniques (technical report)

被引:787
作者
Mocak, J
Bond, AM
Mitchell, S
Scollary, G
机构
[1] UNIV MELBOURNE, SCH CHEM, PARKVILLE, VIC 3052, AUSTRALIA
[2] SLOVAK UNIV TECHNOL BRATISLAVA, DEPT ANALYT CHEM, BRATISLAVA 81237, SLOVAKIA
[3] MONASH UNIV, DEPT CHEM, CLAYTON, VIC 3168, AUSTRALIA
关键词
D O I
10.1351/pac199769020297
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Traditional methods for determining the limit of detection (LOD) and the limit of quantification (LOQ), based on the IUPAC and ACS definitions, often are unsatisfactory. Consequently, a new, simple and statistically correct way of obtaining both the LOD and LOQ values has been derived and compared to commonly used methods. The new Upper Limit Approach, ULA, calculates the upper confidence limit of an individual blank signal using a critical value of the t- distribution and standard error of estimate (residual standard deviation) of regression. The uncertainty of the calibration plot position, its intercept and the mean blank signal are taken also into consideration. The proper choice of calibration model and calibration design also are discussed in detail. An improved derivation of the signal value relevant to the LOQ is based on the use of the same significance level needed for defining the LOD. The concepts developed in this paper have been applied to the determination of cadmium by five common techniques of electrochemical trace analysis (d.c. tast polarography, differential pulse polarography, linear sweep stripping voltammetry, differential pulse stripping voltammetry, and potentiometric stripping analysis) under equivalent (as possible) conditions. The lowest LOD and LOQ values, obtained by the new reliable ULA method, were 1.0x10(-9) mol/L and 3.1x10(-9) mol/L Cd, resp., for differential pulse stripping voltammetry and significance level alpha=0.01. The relevant LOD and LOQ values for alpha=0.05 are 6.6x10(-10) mol/L and 2.0x10(-9) mol/L Cd, resp. Potentiometric stripping analysis provided similar results.
引用
收藏
页码:297 / 328
页数:32
相关论文
共 58 条
[1]  
[Anonymous], 1987, ANALYST, V112, P199
[2]  
[Anonymous], 1980, ANAL CHEM, V52, P2242
[3]  
[Anonymous], 1976, PURE APPL CHEM, V45, P99, DOI DOI 10.1351/PAC197645020099
[4]  
[Anonymous], 1970, STAT INTRO ANAL
[5]  
[Anonymous], 1978, SPECTROCHIM ACTA, VB33, P242
[6]  
Bond A.M., 1980, MODERN POLAROGRAPHIC
[7]   LIMIT OF DETECTION AND LIMIT OF DETERMINATION AS CRITICAL PERFORMANCE-CHARACTERISTICS OF COMPLETE MEASURING METHODS IN THE FIELD OF ENVIRONMENTAL-ANALYSIS [J].
BOS, U ;
JUNKER, A .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1983, 316 (02) :135-141
[8]   DETECTION LIMITS AND SPECTRAL INTERFERENCES IN ATOMIC-EMISSION SPECTROMETRY [J].
BOUMANS, PWJM .
ANALYTICAL CHEMISTRY, 1994, 66 (08) :A459-A467
[10]   ANALYTICAL RANGE [J].
BUTLER, LRP .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1983, 38 (5-6) :913-919