Development of imaging selection criteria and procedures should precede cephalometric assessment with cone-beam computed tomography

被引:101
作者
Farman, Allan G. [1 ]
Scarfe, William C. [1 ]
机构
[1] Univ Louisville, Sch Dent, Dept Surg & Hosp Dent, Div Radiol & Imaging Sci, Louisville, KY 40292 USA
关键词
D O I
10.1016/j.ajodo.2005.10.021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Cone-beam computed tomography (CBCT) systems for craniofacial imaging are now available from several manufacturers. CBCT potentially provides opportunities for 3-dimensional cephalometrics in orthodontic assessment of bony landmarks and air-bounded surfaces such as the facial skin. Two-dimensional cephalogram simulation could facilitate the transfer of growth projections from existing data sets as a starting point for use of a new 3-dimensional paradigm. Three methods are described to simulate conventional 2-dimensioinal cephalograms from CBCT images and volumetric data sets. However, certain precautions are required to assure that selection criteria and imaging parameters guarantee a radiation dose that is as low as reasonably achievable.
引用
收藏
页码:257 / 265
页数:9
相关论文
共 13 条
[1]  
Aboudara C A, 2003, Orthod Craniofac Res, V6 Suppl 1, P173, DOI 10.1034/j.1600-0544.2003.253.x
[2]  
Baumrind S, 2003, Orthod Craniofac Res, V6 Suppl 1, P132, DOI 10.1034/j.1600-0544.2003.246.x
[3]  
Chidiac J J, 2002, Orthod Craniofac Res, V5, P104, DOI 10.1034/j.1600-0544.2002.01170.x
[4]   From 2-dimensional cephalograms to 3-dimensional computed tomography scans [J].
Halazonetis, DJ .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 127 (05) :627-637
[5]   At what resolution should I scan cephalometric radiographs? [J].
Halazonetis, DJ .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2004, 125 (01) :118-119
[6]   Cephalometric digitization: A determination of the minimum scanner settings necessary for precise landmark identification [J].
Held, CL ;
Ferguson, DJ ;
Gallo, MW .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2001, 119 (05) :472-481
[7]   Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography [J].
Hilgers, ML ;
Scarfe, WC ;
Scheetz, JP ;
Farman, AG .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (06) :803-811
[8]  
LUDLOW JB, 2005, P 15 C INT ASS DENT
[9]  
Mah J, 2003, Orthod Craniofac Res, V6 Suppl 1, P10, DOI 10.1034/j.1600-0544.2003.230.x
[10]  
Maki K, 2003, Orthod Craniofac Res, V6 Suppl 1, P95, DOI 10.1034/j.1600-0544.2003.241.x