Computational Modeling of Microarterial Anastomoses With Size Discrepancy (Small-to-Large)

被引:34
作者
Rickard, Rory F. [1 ]
Meyer, Chris [2 ]
Hudson, Don A. [1 ]
机构
[1] Univ Cape Town, Dept Plast Surg, ZA-7925 Cape Town, South Africa
[2] Univ Cape Town, Dept Mech Engn, ZA-7925 Cape Town, South Africa
关键词
microsurgery; arterial size mismatch; end-to-end anastomosis; computational fluid dynamics; hemodynamics; TUBULAR EXPANSION; HUMAN-PLATELETS; SHEAR-STRESS; BLOOD-FLOW; FREE-FLAP; VESSELS; DISTAL; DIAMETER; ARTERY;
D O I
10.1016/j.jss.2008.02.038
中图分类号
R61 [外科手术学];
学科分类号
100210 [外科学];
摘要
Objective. Among Causes of anastomotic failure in microvascular surgery is vessel size mismatch. Where the option of an end-to-side anastomosis is unavailable, an end-to-end construct must be used. Several end-to-end techniques are described to deal with size mismatch. The aim of this study was to numerically model arterial flow patterns and wall shear stresses in four idealized end-to-end anastomoses, where the upstream or recipient artery is smaller. The four techniques modeled were: an invaginating anastomosis; a fish-mouth incision of the smaller vessel; an oblique section of the smaller vessel; and a wedge excision of the larger vessel. Materials and methods. Flow rate in the right femoral artery of a single outbred male Wistar rat was recorded by transit time ultrasound. Initially, upstream vessel diameter in the models was set at 1 mm, and downstream at 2 mm. The wedge technique was further modeled using a shorter wedge, and using a downstream vessel diameter of 3 mm. Walls were deemed noncompliant. Flow was modeled by the finite volume method using the commercially available computational fluid dynamics code Fluent (Fluent Inc., Lebanon, NH; http://www.fluent.com). Results. Ring vortices were seen in the invagination and fish-mouth models and showed similar characteristics, although they were less pronounced in the fish-mouth model. The oblique section model demonstrated complex, spiral, counter-rotating vortices that dissipated downstream. Flow separation was least in the first wedge model, with centralization of flow during high but decelerating flow rate. Shortening the wedge length or increasing the downstream vessel diameter to 3 mm led to flow separation. Wall shear stresses were broadly similar for all constructs. Conclusion. Of those modeled, excision of a wedge of the larger vessel proved the best construct. Where a vessel diameter ratio is 1:2, wedge length should be twice the diameter of the larger vessel. A vessel ratio of 1:3 leads to flow separation when using the wedge technique. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 27 条
[1]
THE VASCULAR TERRITORIES OF THE SUPERIOR EPIGASTRIC AND THE DEEP INFERIOR EPIGASTRIC SYSTEMS [J].
BOYD, JB ;
TAYLOR, GI ;
CORLETT, R .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1984, 73 (01) :1-14
[2]
Brener B J, 1974, Surg Gynecol Obstet, V138, P249
[3]
Buchler U, 1979, MICROSURGICAL COMPOS, P83
[4]
Carrel A., 1902, LYON MED, V98, P859
[5]
Non-Newtonian effects of blood flow on hemodynamics in distal vascular graft anastomoses [J].
Chen, Jie ;
Lu, Xi-Yun ;
Wang, Wen .
JOURNAL OF BIOMECHANICS, 2006, 39 (11) :1983-1995
[6]
EXPERIENCE OF 73 FREE GROIN FLAPS [J].
CHUANG, DCC ;
JENG, SF ;
CHEN, HT ;
CHEN, HC ;
WEI, FC .
BRITISH JOURNAL OF PLASTIC SURGERY, 1992, 45 (02) :81-85
[7]
De la Peña-Salcedo JA, 2000, MICROSURG, V20, P173, DOI 10.1002/1098-2752(2000)20:4<173::AID-MICR5>3.0.CO
[8]
2-B
[9]
Influence of non-Newtonian behavior of blood on flow in an elastic artery model [J].
Dutta, A ;
Tarbell, JM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (01) :111-119
[10]
PREFERENTIAL USE OF END-TO-SIDE ARTERIAL ANASTOMOSES IN FREE FLAP TRANSFERS [J].
GODINA, M .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1979, 64 (05) :673-682