Influence of hydroxyapatite microstructure on human bone cell response

被引:100
作者
Rouahi, Myriam
Gallet, Olivier
Champion, Eric
Dentzer, Joseph
Hardouin, Pierre
Anselme, Karine
机构
[1] ICSI, UPR CNRS 9069, F-68057 Mulhouse, France
[2] Lab Rech Biomat & Biotechnol, Boulogne, France
[3] Univ Cergy Pontoise, Lab ERRMECe, Cergy Pontoise, France
[4] CNRS, UMR 6638, Limoges, France
关键词
hydroxyapatite; microporosity; osteoblastic cells; adhesion; protein adsorption;
D O I
10.1002/jbm.a.30682
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Microstructure of calcium phosphate ceramics has been shown to influence long-term in vitro cellular events like proliferation and differentiation, and to favor bone integration in vivo. As long-term cellular events are known to be dependent of early cell adhesion events, we decided to study the in vitro influence of the microstructure of a microporous hydroxyapatite (mHA) and a nonmicroporous hydroxyapatite (pHA) ceramic on serum protein adsorption and SaOs-2 human bone cells attachment after 30 min, 1, 4, and 24 h and cell growth after 96 h. Plastic coverslips were used as controls. Hydroxyapatite composition of mHA and pHA was confirmed by X-ray diffraction and Fourier transform infra-red spectroscopy. The surface energies of ceramics were calculated from contact-angle measurements in di-iodomethane, water or complete culture medium. The total surface energy was 44.8 mJ/m(2) for pHA and 48.7 mJ/m(2) for plastic. The contact-angle measurement was impossible on mHA likely because they displayed 12% of open microporosity, pHA ceramic exhibiting only closed pores (2.5%). Moreover, the roughness amplitude was largely higher on mHA (Sa = 4.35 mu m) than on pHA (Sa = 0.065 mu m) and plastic (Sa = 0.042 mu m). Three different techniques were used to evaluate protein adsorption on the ceramics. SDS-PAGE of desorbed proteins demonstrated that more proteins desorbed from mHA (66.02 mu g/m(2)) than from pHA (17.2 mu g/m(2)) or plastic (0.08 mu g/m(2)). A new method was used to evaluate in situ the quantity of adsorbed total proteins: the temperature-programmed desorption (TPD) analysis coupled with mass spectrometry. The TPD analysis confirmed that 10-fold more proteins adsorbed on mHA compared with those on pHA. A direct immunolabeling on ceramics revealed than more fibronectin and serum albumin adsorbed on microporous ceramic than on dense ceramic. The morphology of SaOs-2 cells was the same on all the substrates after 30 min. At later time points, cell morphology on mHA was radically different than on other surfaces, with the particularity of the cytoplasmic edge that appeared undistinguishable from the surface. Only the extremity of the cells and lamellipodia were visible. Cells seemed like "adsorbed" by the mHA surface, whereas on plastic and pHA surfaces the cells displayed classical aspects of polygonal spreading. The cells displayed on mHA the highest initial attachment potential after 30 min, 1, 4, 24 h but the lower proliferation potential after four days. This study confirms that a microporous ceramic surface can modulate the adsorption of proteins and further the adhesion and proliferation of human bone cells. (c) 2006 Wiley Periodicals, Inc.
引用
收藏
页码:222 / 235
页数:14
相关论文
共 56 条
[1]   REORGANIZATION OF SUBSTRATUM-BOUND FIBRONECTIN ON HYDROPHILIC AND HYDROPHOBIC MATERIALS IS RELATED TO BIOCOMPATIBILITY [J].
ALTANKOV, G ;
GROTH, T .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (9-10) :732-737
[2]   Porosity variation in hydroxyapatite and osteoblast morphology: a scanning electron microscopy study [J].
Annaz, B ;
Hing, KA ;
Kayser, M ;
Buckland, T ;
Di Silvio, L .
JOURNAL OF MICROSCOPY, 2004, 215 :100-110
[3]  
[Anonymous], 1994, STUDIES INORGANIC CH
[4]   Osteoblast adhesion on biomaterials [J].
Anselme, K .
BIOMATERIALS, 2000, 21 (07) :667-681
[5]  
ANSELME K, 2005, INT CARB C 2005 KOR
[6]   Effect of micro- and macroporosity of bone substitutes on their mechanical properties and cellular response [J].
Bignon, A ;
Chouteau, J ;
Chevalier, J ;
Fantozzi, G ;
Carret, JP ;
Chavassieux, P ;
Boivin, G ;
Melin, M ;
Hartmann, D .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2003, 14 (12) :1089-1097
[7]   Biphasic calcium phosphate concept applied to artificial bone, implant coating and injectable bone substitute [J].
Daculsi, G .
BIOMATERIALS, 1998, 19 (16) :1473-1478
[8]   Effect of serum proteins on osteoblast adhesion to surface-modified bioactive glass and hydroxyapatite [J].
El-Ghannam, A ;
Ducheyne, P ;
Shapiro, IM .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1999, 17 (03) :340-345
[9]   Ceramics in orthopaedics [J].
Hamadouche, M ;
Sedel, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08) :1095-1099
[10]   Microporosity enhances bioactivity of synthetic bone graft substitutes [J].
Hing, KA ;
Annaz, B ;
Saeed, S ;
Revell, PA ;
Buckland, T .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2005, 16 (05) :467-475