Performance of computer-assisted continuous infusion at low concentrations of intravenous sedatives

被引:20
作者
Veselis, RA
Glass, P
Dnistrian, A
Reinsel, R
机构
[1] MEM SLOAN KETTERING CANC CTR,DEPT CRIT CARE MED,NEW YORK,NY 10021
[2] CORNELL UNIV MED COLL,DEPT ANESTHESIOL,NEW YORK,NY
[3] DUKE UNIV,MED CTR,DURHAM,NC
关键词
D O I
10.1097/00000539-199705000-00018
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We studied the performance of a target-controlled drug infusion device, computer-assisted continuous infusion (CACI). Forty-one volunteers received one of midazolam (n=11), propofol (n=10), thiopental (n=10), or fentanyl (n=10) in sedative concentrations. Concentrations were kept constant for 45-70 min at five sequential target concentrations in each subject. Twenty-six subjects had arterial sampling and 15 had venous sampling to determine drug concentrations. Median performance errors, median absolute performance error (MDAPE), wobble, divergence, and median absolute constancy error (MDACE), defined as error around mean actual concentration at each target, were calculated. CACI demonstrated significant performance errors, which were different among drugs. MDAPE (5%-95% confidence interval) ranged from 22.9% (12.1%-39.6%) for propofol to 82.2% (36.0%-183.0%) for midazolam. Although performance errors could be large, CACI was able to maintain a constant serum concentration over time very successfully. The MDACE ranged from 5.6% (3.9%-17.3%) for fentanyl to 11.2% (8.9%-20.4%) for propofol. Few differences occurred between arterial and venous sampling, although when they occurred, arterial samples indicated larger errors. It is concluded that CACI is very successful at maintaining constant serum concentrations of these drugs at sedative concentrations. Arterial sampling should be used when the performance characteristics of an infusion device are being tested. However, venous sampling may be adequate to determine serum concentrations when a pseudo-steady state has been achieved.
引用
收藏
页码:1049 / 1057
页数:9
相关论文
共 27 条
[1]   AN EVALUATION OF THE ACCURACY OF PHARMACOKINETIC DATA FOR THE COMPUTER-ASSISTED INFUSION OF ALFENTANIL [J].
AUSEMS, ME ;
STANSKI, DR ;
HUG, CC .
BRITISH JOURNAL OF ANAESTHESIA, 1985, 57 (12) :1217-1225
[2]  
BUHRER M, 1992, ANESTHESIOLOGY, V77, P226
[3]   DETERMINATION OF THIOPENTAL MEASURED IN HUMAN BLOOD BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CELARDO, A ;
BONATI, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 527 (01) :220-225
[6]   PHARMACOKINETIC MODEL SELECTION FOR TARGET CONTROLLED INFUSIONS OF PROPOFOL - ASSESSMENT OF 3 PARAMETER SETS [J].
COETZEE, JF ;
GLEN, JB ;
WIUM, CA ;
BOSHOFF, L .
ANESTHESIOLOGY, 1995, 82 (06) :1328-1345
[7]   PLASMA DRUG EFFLUX - A NEW APPROACH TO OPTIMIZATION OF DRUG INFUSION FOR CONSTANT BLOOD-CONCENTRATION OF THIOPENTAL AND METHOHEXITAL [J].
CRANKSHAW, DP ;
BOYD, MD ;
BJORKSTEN, AR .
ANESTHESIOLOGY, 1987, 67 (01) :32-41
[8]   Intravenous drug delivery systems: Toward an intravenous ''vaporizer'' [J].
Egan, TD .
JOURNAL OF CLINICAL ANESTHESIA, 1996, 8 :S8-S14
[9]  
GEPTS E, 1987, ANESTH ANALG, V66, P1256
[10]   PHARMACOKINETICS OF THIOPENTONE - EFFECTS OF ENFLURANE AND NITROUS-OXIDE ANESTHESIA AND SURGERY [J].
GHONEIM, MM ;
VANHAMME, MJ .
BRITISH JOURNAL OF ANAESTHESIA, 1978, 50 (12) :1237-1242