Quantification from highly drifted and overlapped chromatographic peaks using second-order calibration methods

被引:64
作者
Comas, E [1 ]
Gimeno, RA [1 ]
Ferré, J [1 ]
Marcé, RM [1 ]
Borrull, F [1 ]
Rius, FX [1 ]
机构
[1] Univ Rovira & Virgili, Dept Analyt Chem & Organ Chem, Tarragona, Spain
关键词
peak overlap; second-order calibration; GRAM; PARAFAC; MCR-ALS; water analysis; uncertainty reduction; pesticides; phenolic compounds;
D O I
10.1016/j.chroma.2004.02.069
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
For determining low levels of pesticides and phenolic compounds in river and wastewater samples by high performance liquid chromatography (HPLC), solid phase extraction (SPE) is commonly used before the chromatographic separation. This preconcentration step is not necessarily selective for the analytes of interest and it may retain other compounds of similar characteristics as well. In this case, we present, humic and fulvic acids caused a large baseline drift and overlapped the analytes to be quantified. The inaccurate determinations of the area of the peaks of these analytes made it difficult to quantify them with univariate calibration. Here we compare three second-order calibration algorithms (generalized rank annihilation method (GRAM), parallel factor analysis (PARAFAC) and multivariate curve resolution-alternating least squares (MCR-ALS)) which efficiently solve this problem. These methods use second-order data, i.e., a matrix of responses for each peak, which is easily obtained with a high performance liquid chromatography-diode array detector (HPLC-DAD). With these methods, the area does not need to be directly measured and predictions are more accurate. They also save time and resources because they can quantify analytes even if the peaks are not resolved. GRAM and PARAEAC require trilinear data. Biased and imprecise concentrations (relative standard deviation, %R.S.D. = 34) were obtained without correcting the time-shift. Hence, a time-shift correction algorithm to align the peaks was needed to obtain accurate predictions. MCR-ALS was the most robust to the time-shift. All three algorithms provided similar mean predictions, which were comparable to those obtained when sulfite was added to the samples. However, the predictions for the different replicates were more similar for the second-order algorithms (%R.S.D. = 3) than the ones obtained by univariate calibration after the sulfite addition (%R.S.D. = 13). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 202
页数:8
相关论文
共 34 条
[1]
[Anonymous], 1998, Multi-way Analysis in the Food Industry: Models, Algorithms and Applications
[2]
THEORY OF ANALYTICAL-CHEMISTRY [J].
BOOKSH, KS ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :A782-A791
[3]
A new efficient method for determining the number of components in PARAFAC models [J].
Bro, R ;
Kiers, HAL .
JOURNAL OF CHEMOMETRICS, 2003, 17 (05) :274-286
[4]
PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[5]
Multivariate calibration - What is in chemometrics for the analytical chemist? [J].
Bro, R .
ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) :185-194
[6]
Chen ZP, 1999, J CHEMOMETR, V13, P15, DOI 10.1002/(SICI)1099-128X(199901/02)13:1<15::AID-CEM527>3.0.CO
[7]
2-I
[8]
Using second-order calibration to identify and quantify aromatic sulfonates in water by high-performance liquid chromatography in the presence of coeluting interferences [J].
Comas, E ;
Gimeno, RA ;
Ferré, J ;
Marcé, RM ;
Borrull, F ;
Rius, FX .
JOURNAL OF CHROMATOGRAPHY A, 2003, 988 (02) :277-284
[9]
Time shift correction in second-order liquid chromatographic data with iterative target transformation factor analysis [J].
Comas, E ;
Gimeno, RA ;
Ferré, J ;
Marcé, RM ;
Borrull, F ;
Rius, FX .
ANALYTICA CHIMICA ACTA, 2002, 470 (02) :163-173
[10]
Selecting significant factors by the noise addition method in principal component analysis [J].
Dable, BK ;
Booksh, KS .
JOURNAL OF CHEMOMETRICS, 2001, 15 (07) :591-613