Characterizing high-affinity antigen/antibody complexes by kinetic- and equilibrium-based methods

被引:103
作者
Drake, AW
Myszka, DG
Klakamp, SL
机构
[1] Abgenix Inc, Fremont, CA 94555 USA
[2] Univ Utah, Ctr Biomol Interact Anal, Salt Lake City, UT 84132 USA
关键词
surface plasmon resonance; Biacore; KinExA; monoclonal antibodies; picomolar and nanomolar affinities; equilibrium dissociation constants; kinetic rate constants;
D O I
10.1016/j.ab.2003.12.025
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two biophysical methods, Biacore and KinExA, were used to kinetically and thermodynamically characterize high-affinity antigen/antibody complexes. Three to five independent experiments were performed on each platform with three different antigen/antibody complexes possessing nanomolar to picomolar equilibrium dissociation constants. By monitoring the dissociation phase on Biacore for 4 h, we were able to measure dissociation rate constants (k(d)) on the order of 1 x 10(-5) s(-1). To characterize high-affinity interactions by KinExA, samples needed to be equilibrated for up to 35 h to reach equilibrium. In the end, we show that similar kinetic rate constants and affinities were determined with both solution-phase and solid-phase methodologies. These results help further validate both interaction technologies and illustrate their suitability for characterizing extremely high-affinity interactions. (C) 2004 Abgenix Inc., Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 22 条
[1]   A novel strategy for generating monoclonal antibodies from single, isolated lymphocytes producing antibodies of defined specificities [J].
Babcook, JS ;
Leslie, KB ;
Olsen, OA ;
Salmon, RA ;
Schrader, JW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (15) :7843-7848
[2]  
*BIAC INC, BIAAPPLICATIONS HDB
[3]   Metal binding properties of a monoclonal antibody directed toward metal-chelate complexes [J].
Blake, DA ;
Chakrabarti, P ;
Khosraviani, M ;
Hatcher, FM ;
Westhoff, CM ;
Goebel, P ;
Wylie, DE ;
Blake, RC .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1996, 271 (44) :27677-27685
[4]   Automated kinetic exclusion assays to quantify protein binding interactions in homogeneous solution [J].
Blake, RC ;
Pavlov, AR ;
Blake, DA .
ANALYTICAL BIOCHEMISTRY, 1999, 272 (02) :123-134
[5]   Selective binding of polychlorinated biphenyl congeners by a monoclonal antibody: Analysis by kinetic exclusion fluorescence immunoassay [J].
Chiu, YW ;
Li, QX ;
Karu, AE .
ANALYTICAL CHEMISTRY, 2001, 73 (22) :5477-5484
[6]  
DAVIS CG, 2003, METHOD MOL BIOL, V248, P191
[7]   Direct comparison of binding equilibrium, thermodynamic, and rate constants determined by surface- and solution-based biophysical methods [J].
Day, YSN ;
Baird, CL ;
Rich, RL ;
Myszka, DG .
PROTEIN SCIENCE, 2002, 11 (05) :1017-1025
[8]   Effect of hydrogel matrix on binding kinetics of protein-protein interactions on sensor surface [J].
Fong, CC ;
Wong, MS ;
Fong, WF ;
Yang, MS .
ANALYTICA CHIMICA ACTA, 2002, 456 (02) :201-208
[9]   Monoclonal antibodies that recognize minimal differences in the three-dimensional structures of metal-chelate complexes [J].
Jones, RM ;
Yu, HN ;
Delehanty, JB ;
Blake, DA .
BIOCONJUGATE CHEMISTRY, 2002, 13 (03) :408-415
[10]   Experimental design for kinetic analysis of protein-protein interactions with surface plasmon resonance biosensors [J].
Karlsson, R ;
Falt, A .
JOURNAL OF IMMUNOLOGICAL METHODS, 1997, 200 (1-2) :121-133