Guideline for the production of multicentre physiological reference values using the same measurement system.: A proposal of the Catalan Association for Clinical Laboratory Sciences

被引:31
作者
Fuentes-Arderiu, X [1 ]
Mas-Serra, R
Alumà-Trullàs, A
Martí-Marcet, MI
Dot-Bach, D
机构
[1] Hosp Univ Bellvitge, Serv Bioquim Clin, Lhospitalet De Llobregat 08907, Catalonia, Spain
[2] Roche Diagnost, Barcelona, Spain
[3] DAP Badalona & St Adria, Lab Clin Barcelones Nord, Badalona, Spain
[4] Consorci Sanitari Terrassa, Lab Anal Clin, Terrassa, Catalonia, Spain
[5] Consorci Sanitari Integral, Lab Hosp Hosp, Lhospitalet De Llobregat, Catalonia, Spain
关键词
in vitro diagnostics industry; reference intervals; reference limits; reference values;
D O I
10.1515/CCLM.2004.130
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
This article is intended as a guide for the production of biological reference values of healthy people (physiological reference values) by several clinical laboratories using the same measurement system. This guide is a proposal from the Catalan Association of Clinical Laboratory Sciences to be applied worldwide at a regional level. This guide makes it possible for all clinical laboratories in a region using the same measurement system to adopt the same physiological reference limits. The model presented here is based on the assumption that the production of physiological reference values is a professional task that should be shared by both clinical laboratories and the in vitro diagnostics industry.
引用
收藏
页码:778 / 782
页数:5
相关论文
共 22 条
[1]   A model for a multicentre approach to the derivation of reference intervals for thyroid hormones and testosterone for laboratories using identical analysers [J].
Andrew, CE ;
Hanning, I ;
McBain, AM ;
Moody, D ;
Price, A .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2000, 38 (10) :1013-1019
[2]  
[Anonymous], 1999, WHONCDNCS992
[3]  
[Anonymous], 15189 ISO
[4]  
Conover W, 1980, PRACTICAL NONPARAMET, P229
[5]  
Cruz-Carlos L. M., 2003, Clinica Chimica Acta, V338, P165, DOI 10.1016/j.cccn.2003.09.001
[6]   PROCESSING DATA FOR OUTLIERS [J].
DIXON, WJ .
BIOMETRICS, 1953, 9 (01) :74-89
[7]  
DYBKAER R, 1987, CLIN CHIM ACTA, V170, pS33, DOI 10.1016/0009-8981(87)90152-5
[8]   Regional reference values for some quantities measured with the ADVIA Centaur analyser.: A model of co-operation between the in vitro diagnostic industry and clinical laboratories [J].
Ferré-Masferrer, M ;
Fuentes-Arderiu, X ;
Gomà-Llongueras, M ;
Alumà-Trullàs, A ;
Aramendi-Ramos, M ;
Castaño-Vidriales, JL ;
Esteban-Salan, M ;
Graells-Ferrer, M ;
Jiménez-González, A ;
Jiménez-Lobo, C ;
López-Esparza, M ;
Parés-Pollán, L ;
Regulez-Uranga, M ;
Riesco-Prieto, M ;
Rodríguez-Camba, A ;
Vidal-Martínez, J .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2001, 39 (02) :166-169
[9]   Multicentric reference values for some quantities measured with Tina-Quant® reagents systems and RD/Hitachi analysers [J].
Fuentes-Arderiu, X ;
Ferré-Masferrer, M ;
González-Alba, JM ;
Escolà-Aliberas, J ;
Balsells-Rosello, D ;
Blanco-Cristobal, C ;
González-Cruz, E ;
Ibarz-Escuer, M ;
Latorre-Marcellán, P ;
Lugo-Arocena, J ;
Mar-Medina, C ;
Muros-De-Fuentes, M ;
Vicens-Manero, M .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2001, 61 (04) :273-276
[10]   Multicentric reference values for some quantities measured with the Elecsys 2010® analyser [J].
Fuentes-Arderiu, X ;
Ferrer-Masferrer, M ;
González-Alba, JM ;
Villarino-González, MI ;
Arrimadas-Esteban, E ;
Cabrero-Olivé, D ;
Cándenas-Arroyo, M ;
García-García, D ;
García-Lario, JV ;
Idoate-Cervantes, I ;
León-López, C ;
López-Lazareno, N ;
Mar-Medina, C ;
Martí-Marcet, I ;
Mauri-Dot, M ;
Pérez-Valero, V ;
Reta-Manterola, A ;
Sánchez-Eixeres, MR .
CLINICA CHIMICA ACTA, 2001, 304 (1-2) :143-146