Respiratory mechanics during xenon anesthesia in pigs -: Comparison with nitrous oxide

被引:19
作者
Calzia, E [1 ]
Stahl, W [1 ]
Handschuh, T [1 ]
Marx, T [1 ]
Fröba, G [1 ]
Bäder, S [1 ]
Georgieff, M [1 ]
Radermacher, P [1 ]
机构
[1] Univ Hosp Ulm, Dept Anesthesiol, D-89075 Ulm, Germany
关键词
experimental bronchoconstriction; general anesthesia; lung function;
D O I
10.1097/00000542-199911000-00030
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Because of its high density and viscosity, xenon (Xe) may influence respiratory mechanics when used as an inhaled anesthetic Therefore the authors studied respiratory mechanics during xenon and nitrous oxide (N2O) anesthesia before and during methacholine-induced bronchoconstriction. Methods: Sixteen pentobarbital-anesthetized pigs initially were ventilated with 70% nitrogen-oxygen. Then they were randomly assigned to a test period of ventilation with either 70% xenon-oxygen or 70% N2O-oxygen (n = 8 for each group). Nitrogen-oxygen ventilation was then resumed. Tidal volume and inspiratory flow rate were set equally throughout the study. During each condition the authors measured peak and mean airway pressure (P-max and P-mean) and airway resistance (R-aw) by the end-inspiratory occlusion technique. This sequence was then repeated during a methacholine infusion. Results: Both before and during methacholine airway resistance was significantly higher with xenon-oxygen (4.0 +/- 1.7 and 10.9 +/- 3.8 cm H2O . s(-1) . l(-1), mean +/- SD) when compared to nitrogen-oxygen (2.6 +/- 1.1 and 5.8 +/- 1.4 cm H2O . s(-1) . l(-1), P < 0.01) and N2O-oxygen (2.9 +/- 0.8 and 7.0 +/- 1.9, P < 0.01). P-max and P(mea)n did not differ before bronchoconstriction, regardless of the inspired gas mixture. During bronchoconstriction P-max and P-mean both were significantly higher with xenon-oxygen (P-max, 33.1 +/- 5.5 and P-mean, 11.9 +/- 1.6 cm H2O) when compared to N2O-oxygen (28.4 +/- 5.7 and 9.5 +/- 1.6 cm H2O, P < 0.01) and nitrogen-oxygen (28.0 +/- 4.4 and 10.6 +/- 1.3 cm H2O, P < 0.01). Conclusions: Airway pressure and resistance are increased during xenon anesthesia. This response is moderate and not likely to assume major importance for the general use of xenon in anesthesia.
引用
收藏
页码:1378 / 1386
页数:9
相关论文
共 33 条
[1]   EFFECT OF VALVE CLOSURE TIME ON THE DETERMINATION OF RESPIRATORY RESISTANCE BY FLOW INTERRUPTION [J].
BATES, JHT ;
HUNTER, IW ;
SLY, PD ;
OKUBO, S ;
FILIATRAULT, S ;
MILICEMILI, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1987, 25 (02) :136-140
[2]   ANALYSIS OF THE BEHAVIOR OF THE RESPIRATORY SYSTEM WITH CONSTANT INSPIRATORY FLOW [J].
BATES, JHT ;
ROSSI, A ;
MILICEMILI, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (06) :1840-1848
[3]   Respiratory resistance, oil-water solubility, and mental effects of argon, compared with helium and nitrogen [J].
Behnke, AR ;
Yarbrough, OD .
AMERICAN JOURNAL OF PHYSIOLOGY, 1939, 126 (02) :409-415
[4]   PULMONARY GAS-EXCHANGE DURING ALTERED DENSITY GAS BREATHING [J].
CHRISTOPHERSON, SK ;
HLASTALA, MP .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (01) :221-225
[5]   DISTRIBUTION OF PULMONARY RESISTANCE - EFFECTS OF GAS-DENSITY, VISCOSITY, AND FLOW-RATE [J].
DRAZEN, JM ;
LORING, SH ;
INGRAM, RH .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 41 (03) :388-395
[6]   PARTITIONING OF RESPIRATORY FLOW RESISTANCE IN MAN [J].
FERRIS, BG ;
MEAD, J ;
OPIE, LH .
JOURNAL OF APPLIED PHYSIOLOGY, 1964, 19 (04) :653-&
[7]   THE CONCEPT OF DEADSPACE WITH SPECIAL REFERENCE TO THE SINGLE BREATH TEST FOR CARBON-DIOXIDE [J].
FLETCHER, R ;
JONSON, B ;
CUMMING, G ;
BREW, J .
BRITISH JOURNAL OF ANAESTHESIA, 1981, 53 (01) :77-88
[8]   EFFECT OF GAS DENSITY ON DYNAMIC PULMONARY COMPLIANCE [J].
FORKERT, L ;
WOOD, LDH ;
CHERNIACK, RM .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 39 (06) :906-910
[9]   VA-Q INHOMOGENEITY AND AADO2 IN MAN DURING EXERCISE - EFFECT OF SF6 BREATHING [J].
GLEDHILL, N ;
FROESE, AB ;
BUICK, FJ ;
BRYAN, AC .
JOURNAL OF APPLIED PHYSIOLOGY, 1978, 45 (04) :512-515
[10]   HELIUM-OXYGEN MIXTURES IN INTUBATED PATIENTS WITH STATUS-ASTHMATICUS AND RESPIRATORY-ACIDOSIS [J].
GLUCK, EH ;
ONORATO, DJ ;
CASTRIOTTA, R .
CHEST, 1990, 98 (03) :693-698