Optimization of sodium removal in paired filtration dialysis by single pool sodium and conductivity kinetic models

被引:30
作者
DiFilippo, S
Corti, M
Andrulli, S
Pontoriero, G
Manzoni, C
Locatelli, F
机构
[1] Nephrology Department, Lecco Hospital, Lecco
关键词
paired filtration dialysis; hemodiafiltration; sodium kinetic model; conductivity kinetic model;
D O I
10.1159/000170315
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Sodium removal is one of the main factors affecting intradialytic cardiovascular stability and interdialytic hypertension, and its removal should therefore be individualized, The aims of this study were: (1) to test the ability of a single-pool variable volume (SPVV) sodium kinetic model (NaKM) to optimize sodium removal in paired filtration dialysis (PFD), and (2) to test a SPW conductivity kinetic model (CKM) in order to verify whether CKM can be used as an alternative for NaKM in estimating sodium balance, The mean difference between the NaKM-predicted and measured end-PFD plasma water ionized sodium concentrations was 0.00 +/- 0.55 mEq/l, which means that the model has an imprecision of less than or equal to 1.1 mEq/l. The mean difference between predicted and measured sodium removal was 0.21 +/- 16.86 mEq/session, which means a model overestimate of 0.21 mEq/session. The mean difference between the CKM-predicted and measured end-PFD ultra-filtrate conductivity was 0.01 +/- 0.05 mS/cm, which means an inaccuracy of the model of 0.01 mS/cm and an imprecision of less than or equal to 0.1 mS/cm. The regression in the ionized sodium concentration measured in plasma or blood oil the conductive values of the ultrafiltrate shows an error of less than or equal to 2 mEq/l in the prediction of the ionized sodium concentration in blood by means of ultrafiltrate conductivity measurements, These results demonstrate that both models make it possible to obtain a level of dialytic sodium removal that is almost equivalent to interdialytic sodium loading. Moreover, gives that it does not require blood sampling and the possibility of making repeated and inexpensive ultrafiltrate conductivity measurements, the CKM allows online monitoring of programmed sodium removal.
引用
收藏
页码:34 / 44
页数:11
相关论文
共 9 条
[1]  
[Anonymous], 1983, REPLACEMENT RENAL FU
[2]  
BOTELLA J, 1986, NEPHROL DIAL TRANSPL, V1, P101
[3]   DIALYSIS HYPOTENSION - A HEMODYNAMIC ANALYSIS [J].
DAUGIRDAS, JT .
KIDNEY INTERNATIONAL, 1991, 39 (02) :233-246
[4]  
GOTCH F A, 1983, Blood Purification, V1, P9, DOI 10.1159/000166439
[5]   SODIUM AND DIALYSIS - A DEEPER INSIGHT [J].
LOCATELLI, F ;
PONTI, R ;
PEDRINI, L ;
DIFILIPPO, S .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1989, 12 (02) :71-74
[6]  
Locatelli F, 1989, Contrib Nephrol, V70, P260
[7]   PHYSIOLOGICAL AND PHARMACOLOGICAL DIALYSATE SODIUM CONCENTRATIONS [J].
LOCATELLI, F ;
PEDRINI, L ;
PONTI, R ;
COSTANZO, R ;
DIFILIPPO, S ;
MARAI, P ;
POZZI, C ;
BONACINA, GP .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1982, 5 (01) :17-24
[8]  
Sherman R., 1988, SEMIN DIALYSIS, V1, P136, DOI [DOI 10.1111/J.1525-139X.1988.TB00747.X, 10.1111/j.1525-139X.1988.tb00747.x]
[9]   UTILITY OF EXPRESSING SERUM SODIUM PER UNIT OF WATER IN ASSESSING HYPONTREMIA [J].
WAUGH, WH .
METABOLISM, 1969, 18 (08) :706-+