Blood compatibility of polyurethane immobilized with acrylic acid and plasma grafting sulfonic acid

被引:39
作者
Lv, Q [1 ]
Cao, CB [1 ]
Zhu, HS [1 ]
机构
[1] Beijing Inst Technol, Res Ctr Mat Sci, Beijing 100081, Peoples R China
关键词
D O I
10.1023/B:JMSM.0000026382.34900.b6
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Sulfonic and carboxyl groups can effectively improve the blood compatibility of polyurethane. But it is difficult to obtain an optimum ratio of the two groups. In this article, polyurethane (PU) was dissolved with acrylic acid in a tetrahydrofuran solution and then spread on the glass plate to produce a film. At the same time, acrylic acid partly polymerized and immobilized with the PU films. The films (PU-AA) were exposed to sulfur dioxide plasma to graft sulfonic acid group on its surfaces. Through adjusting the quantity of acrylic acid and the plasma reaction condition, the antithrombin of polyurethane can be improved. The surface-modified PUs were characterized by attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), X-ray photoelectron spectroscope (XPS) and a contact angle goniometer. The blood compatibility of the films was examined by using thrombin time (TT), activated partial thromboplastin time (APTT) and prothrombin time (PT). The TT and APTT were significantly prolonged for the surface-modified films of PU-AA by sulfur dioxide plasma and only APTT was elongated for PU-AA. The results suggest that sulfonic acid and acrylic acid have the different effect on the blood compatibility of surface-modified Pus. (C) 2004 Kluwer Academic Publishers.
引用
收藏
页码:607 / 611
页数:5
相关论文
共 21 条
[1]
Synthesis and characterization of heparinized polyurethanes using plasma glow discharge [J].
Bae, JS ;
Seo, EJ ;
Kang, IK .
BIOMATERIALS, 1999, 20 (06) :529-537
[2]
Immobilisation of sulphated hyaluronan for improved biocompatibility [J].
Barbucci, R ;
Magnani, A ;
Rappuoli, R ;
Lamponi, S ;
Consumi, M .
JOURNAL OF INORGANIC BIOCHEMISTRY, 2000, 79 (1-4) :119-125
[3]
In vitro blood compatibility of surface-modified polyurethanes [J].
Bernacca, GM ;
Gulbransen, MJ ;
Wilkinson, R ;
Wheatley, DJ .
BIOMATERIALS, 1998, 19 (13) :1151-1165
[4]
Chen Z, 2000, J APPL POLYM SCI, V76, P382, DOI 10.1002/(SICI)1097-4628(20000418)76:3<382::AID-APP13>3.0.CO
[5]
2-A
[6]
Heparin coating of the stent graft - effects on platelets, coagulation and complement activation [J].
Christensen, K ;
Larsson, R ;
Emanuelsson, H ;
Elgue, G ;
Larsson, A .
BIOMATERIALS, 2001, 22 (04) :349-355
[7]
Polyurethane surfaces modified by amphiphilic polymers:: effects on protein adsorption [J].
Freij-Larsson, C ;
Jannasch, P ;
Wesslén, B .
BIOMATERIALS, 2000, 21 (03) :307-315
[8]
GARNER B, POLYPYRROLE HEPARIN
[9]
Improved cell adhesion by plasma-induced grafting of L-lactide onto polyurethane surface [J].
Hsu, SH ;
Chen, WC .
BIOMATERIALS, 2000, 21 (04) :359-367
[10]
ISHIHARA M, 2000, HCPS MEDIATE CELLULA