Separation of plasma from whole human blood in a continuous cross-flow in a molded microfluidic device

被引:180
作者
VanDelinder, Virginia [1 ]
Groisman, Alex [1 ]
机构
[1] Univ Calif San Diego, Dept Phys, La Jolla, CA 92093 USA
关键词
D O I
10.1021/ac060042r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We designed, fabricated, and tested a microfluidic device for separation of plasma from whole human blood by size exclusion in a cross-flow. The device is made of a single mold of a silicone elastomer poly( dimethylsiloxane) ( PDMS) sealed with a cover glass and is essentially disposable. When loaded with blood diluted to 20% hematocrit and driven with pulsatile pressure to prevent clogging of the channels with blood cells, the device can operate for at least 1 h, extracting similar to 8% of blood volume as plasma at an average rate of 0.65 mu L/min. The flow in the device causes very little hemolysis; the extracted plasma meets the standards for common assays and is delivered to the device outlet similar to 30 s after injection of blood to the inlet. Integration of the cross-flow microchannel array with on-chip assay elements would create a microanalysis system for point-of-care diagnostics, reducing costs, turn-around times, and volumes of blood sample and reagents required for the assays.
引用
收藏
页码:3765 / 3771
页数:7
相关论文
共 28 条
[1]  
[Anonymous], 1987, HDB BIOENGINEERING
[2]   THE BEHAVIOR OF SUSPENSIONS AND MACROMOLECULAR SOLUTIONS IN CROSS-FLOW MICROFILTRATION [J].
BELFORT, G ;
DAVIS, RH ;
ZYDNEY, AL .
JOURNAL OF MEMBRANE SCIENCE, 1994, 96 (1-2) :1-58
[3]   A microchip-based multianalyte assay system for the assessment of cardiac risk [J].
Christodoulides, N ;
Tran, M ;
Floriano, PN ;
Rodriguez, M ;
Goodey, A ;
Ali, M ;
Neikirk, D ;
McDevitt, JT .
ANALYTICAL CHEMISTRY, 2002, 74 (13) :3030-3036
[4]   RAPID METHOD FOR ESTIMATION OF PLASMA HAEMOGLOBIN LEVELS [J].
CRIPPS, CM .
JOURNAL OF CLINICAL PATHOLOGY, 1968, 21 (01) :110-&
[5]   Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications [J].
Crowley, TA ;
Pizziconi, V .
LAB ON A CHIP, 2005, 5 (09) :922-929
[6]  
DRYDEN HL, 1956, HYDRODYNAMICS
[7]  
Fung Y., 1972, Biomechanics: Its Foundations and Objectives
[8]   A microfluidic chemostat for experiments with bacterial and yeast cells [J].
Groisman, A ;
Lobo, C ;
Cho, HJ ;
Campbell, JK ;
Dufour, YS ;
Stevens, AM ;
Levchenko, A .
NATURE METHODS, 2005, 2 (09) :685-689
[9]  
HENDERSON LW, 1986, HEMOFILTRATION
[10]   Sinusoidal crossflow microfiltration device -: experimental and computational flowfield analysis [J].
Mielnik, MM ;
Ekatpure, RP ;
Sætran, LR ;
Schönfeld, F .
LAB ON A CHIP, 2005, 5 (08) :897-903