Feasibility of structural monitoring with vibration powered sensors

被引:161
作者
Elvin, Niell G.
Lajnef, Nizar
Elvin, Alex A.
机构
[1] Michigan State Univ, Dept Civil & Environm Engn, E Lansing, MI 48824 USA
[2] Univ Witwatersrand, Dept Civil & Environm Engn, Johannesburg, South Africa
关键词
D O I
10.1088/0964-1726/15/4/011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Wireless sensors and sensor networks are beginning to be used to monitor structures. In general, the longevity, and hence the efficacy, of these sensors are severely limited by their stored power. The ability to convert abundant ambient energy into electric power would eliminate the problem of drained electrical supply, and would allow indefinite monitoring. This paper focuses on vibration in civil engineering structures as a source of ambient energy; the key question is can sufficient energy be produced from vibrations? Earthquake, wind and traffic loads are used as realistic sources of vibration. The theoretical maximum energy levels that can be extracted from these dynamic loads are computed. The same dynamic loads are applied to a piezoelectric generator; the energy is measured experimentally and computed using a mathematical model. The collected energy levels are compared to the energy requirements of various electronic subsystems in a wireless sensor. For a 5 cm(3) sensor node (the volume of a typical concrete stone), it is found that only extreme events such as earthquakes can provide sufficient energy to power wireless sensors consisting of modem electronic chips. The results show that the optimal generated electrical power increases approximately linearly with increasing sensor mass. With current technology, it would be possible to self-power a sensor node with a mass between 100 and 1000 g for a bridge under traffic load. Lowering the energy consumption of electronic components is an ongoing research effort. It is likely that, as electronics becomes more efficient in the future, it will be possible to power a wireless sensor node by harvesting vibrations from a volume generator smaller than 5 cm(3).
引用
收藏
页码:977 / 986
页数:10
相关论文
共 19 条
[1]   Self-powered signal processing using vibration-based power generation [J].
Amirtharajah, R ;
Chandrakasan, AP .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1998, 33 (05) :687-695
[2]  
BROWNJOHN JWM, 2005, COMMUNICATION
[3]   GPS in dynamic monitoring of long-period structures [J].
Çelebi, M .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2000, 20 (5-8) :477-483
[4]   Modal identification and model updating of a reinforced concrete bridge [J].
El-Borgi, S ;
Choura, S ;
Ventura, C ;
Baccouch, M ;
Cherif, F .
SMART STRUCTURES AND SYSTEMS, 2005, 1 (01) :83-101
[5]   Failure mechanism of concrete - Combined effects of coarse aggregates and strength level [J].
Giaccio, G ;
Zerbino, R .
ADVANCED CEMENT BASED MATERIALS, 1998, 7 (02) :41-48
[6]   Size effects in concrete fracture: Part I, experimental setup and observations [J].
Issa, MA ;
Issa, MA ;
Islam, MS ;
Chudnovsky, A .
INTERNATIONAL JOURNAL OF FRACTURE, 2000, 102 (01) :1-24
[7]  
Kao J., 2001, Doctor of Philosophy Thesis
[8]   Can a coupling coefficient of a piezoelectric device be higher than those of its active material? [J].
Lesieutre, GA ;
Davis, CL .
JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 1997, 8 (10) :859-867
[9]  
Li QS, 2000, EARTHQUAKE ENG STRUC, V29, P1845, DOI 10.1002/1096-9845(200012)29:12<1845::AID-EQE995>3.0.CO
[10]  
2-Q