Development of a β-type Ti-12Mo-5Ta alloy for biomedical applications:: cytocompatibility and metallurgical aspects

被引:70
作者
Gordin, DM
Gloriant, T [1 ]
Texier, G
Thibon, I
Ansel, D
Duval, JL
Nagel, MD
机构
[1] Inst Natl Sci Appl Rennes, Grp Rech Chim Met, GRCM EA 2620, CS 14315, F-35043 Rennes, France
[2] Univ Technol Compiegne, UMR CNRS Genie Biomed 6600, F-60205 Compiegne, France
关键词
D O I
10.1023/B:JMSM.0000036276.32211.31
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Ti-based biocompatible alloys are especially used for replacing failed hard tissue. Some of the most actively investigated materials for medical implants are the beta-Ti alloys, as they have a low elastic modulus (to inhibit bone resorption). They are alloyed with elements such as Nb, Ta, Zr, Mo, and Fe. We have prepared a new beta-Ti alloy that combines Ti with the non-toxic elements Ta and Mo using a vacuum arc-melting furnace and then annealed at 950 degreesC for one hour. The alloy was finally quenched in water at room temperature. The Ti-12Mo-5Ta alloy was characterised by X-ray diffraction, optical microscopy, SEM and EDS and found to have a body-centred-cubic structure (beta-type). It had a lower Young's modulus (about 74 GPa) than the classical alpha/beta Ti-6Al-4V alloy (120 GPa), while its Vickers hardness remained very high (about 303 HV). This makes it a good compromise for a use as a bone substitute. The cytocompatibility of samples of Ti-12Mo-5Ta and Ti-6Al-4V titanium alloys with various surface roughnesses was assessed in vitro using organotypic cultures of bone tissue and quantitative analyses of cell migration, proliferation and adhesion. Mechanically polished surfaces were prepared to produce unorientated residual polished grooves and cells grew to a particularly high density on the smoother Ti-12Mo-5Ta surface tested. (C) 2004 Kluwer Academic Publishers.
引用
收藏
页码:885 / 891
页数:7
相关论文
共 38 条
[1]
Recent developments in microstructure/property relationships of beta titanium alloys [J].
Ankem, S ;
Greene, CA .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1999, 263 (02) :127-131
[2]
[Anonymous], 2000, ELECT BACKSCATTER DI, DOI DOI 10.1103/PhysRevB.97.134104
[3]
The relative influence of the topography and chemistry of TiAl6V4 surfaces on osteoblastic cell behaviour [J].
Anselme, K ;
Linez, P ;
Bigerelle, M ;
Le Maguer, D ;
Le Maguer, A ;
Hardouin, P ;
Hildebrand, HF ;
Iost, A ;
Leroy, JM .
BIOMATERIALS, 2000, 21 (15) :1567-1577
[4]
BANIA PJ, 1993, BETA TITANIUM ALLOYS IN THE 1990S, P3
[5]
Boyan B., 2001, ENG MAT SER, P561
[6]
Role of material surfaces in regulating bone and cartilage cell response [J].
Boyan, BD ;
Hummert, TW ;
Dean, DD ;
Schwartz, Z .
BIOMATERIALS, 1996, 17 (02) :137-146
[7]
Brunette D M, 1988, Int J Oral Maxillofac Implants, V3, P231
[8]
INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS [J].
BUSER, D ;
SCHENK, RK ;
STEINEMANN, S ;
FIORELLINI, JP ;
FOX, CH ;
STICH, H .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07) :889-902
[9]
Visualisation of human plasma fibrinogen adsorbed on titanium implant surfaces with different roughness [J].
Cacciafesta, P ;
Hallam, KR ;
Watkinson, AC ;
Allen, GC ;
Miles, MJ ;
Jandt, KD .
SURFACE SCIENCE, 2001, 491 (03) :405-420
[10]
Variable length scale analysis of surface topography: characterization of titanium surfaces for biomedical applications [J].
Chauvy, PF ;
Madore, C ;
Landolt, D .
SURFACE & COATINGS TECHNOLOGY, 1998, 110 (1-2) :48-56