Theoretical study of incomplete sampling of the first dimension in comprehensive two-dimensional chromatography

被引:116
作者
Seeley, JV [1 ]
机构
[1] Oakland Univ, Dept Chem, Rochester, MI 48309 USA
基金
美国国家科学基金会;
关键词
modulation; sampling theory; comprehensive two-dimensional chromatography;
D O I
10.1016/S0021-9673(02)00461-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The process of regularly transferring material from the primary column to the secondary column is critical in producing comprehensive two-dimensional separations. A series of calculations have been performed to determine how sampling period, duty cycle, and sampling phase affect (1) the fraction of material transferred from the primary column to the secondary column, (2) the accuracy of primary retention time determination, and (3) the effective peak width along the primary retention axis. The results demonstrate that comprehensive two-dimensional separations can be produced without a substantial loss in quantitative precision and with only a moderate loss in primary column resolution if the sampling period is less than 1.5 times the primary peak standard deviation. The quantitative precision of total peak areas (for duty cycles less than 1.0) and primary retention time determination are rapidly reduced as the sampling period is increased above 1.5 times the primary peak standard deviation. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 19 条
[1]   Simple, non-moving modulation interface for comprehensive two-dimensional gas chromatography [J].
Beens, J ;
Adahchour, M ;
Vreuls, RJJ ;
van Altena, K ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (01) :127-132
[2]   Comprehensive two dimensional high-speed gas chromatography with chemometric analysis [J].
Bruckner, CA ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2796-2804
[3]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[4]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPILLARY ZONE ELECTROPHORESIS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :978-984
[5]   EXCHANGE OF COMMENTS ON DATA ACQUISITION FOR CHROMATOGRAPHIC PEAKS [J].
DUELL, KA ;
AVERY, JP ;
ROWLEN, KL ;
BIRKS, JW .
ANALYTICAL CHEMISTRY, 1991, 63 (01) :73-75
[6]   Optimization of the dwell-time for the quantitative analysis by gas chromatography mass spectrometry [J].
Eveleigh, LJ ;
Ducauze, CJ .
JOURNAL OF CHROMATOGRAPHY A, 1997, 765 (02) :241-245
[7]  
GUIOCHON G, 1991, ANAL CHEM, V63, P73, DOI 10.1021/ac00001a013
[8]   A transparent flow gating interface for the coupling of microcolumn LC with CZE in a comprehensive two-dimensional system [J].
Hooker, TF ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1997, 69 (20) :4134-4142
[9]   PRACTICAL CONSIDERATIONS FOR DIGITIZING ANALOG SIGNALS [J].
KELLY, PC ;
HORLICK, G .
ANALYTICAL CHEMISTRY, 1973, 45 (03) :518-527
[10]   TRANSVERSE FLOW GATING INTERFACE FOR THE COUPLING OF MICROCOLUMN-LC WITH CZE IN A COMPREHENSIVE 2-DIMENSIONAL SYSTEM [J].
LEMMO, AV ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1576-1581