Verification of an assay for quantification of hepatitis C virus RNA by use of an analyte-specific reagent and two different extraction methods

被引:13
作者
Forman, MS [1 ]
Valsamakis, A [1 ]
机构
[1] Johns Hopkins Med Inst, Div Microbiol, Baltimore, MD 21287 USA
关键词
D O I
10.1128/jcm.42.8.3581-3588.2004
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Protocols were designed for quantification and detection of hepatitis C virus (HCV) RNA by the use of an analyte-specific reagent (ASR) (Roche COBAS TaqMan48 [CTM48] HCV) after manual and automated RNA extraction. The purposes were to determine (i) assay performance characteristics using manual and automated RNA extraction methods, (ii) whether measurable range and limit of detection (LOD) of the ASR assay were influenced by genotype, and (iii) correlation of quantification by CTM48 HCV ASR and COBAS Monitor HCV v. 2.0. For HCV genotype 1 (Gt1), the lower limits of quantification after manual extraction were slightly lower than those for automated extraction (1.0 versus 1.5 log(10) IU/ml). Results were linear up to the highest concentration tested after extraction by both methods (manual, 6.1 log(10); automated, 6.4 log(10)). Similar results were obtained for Gt2 (1.8 to 6.8 log(10) IU/ml) and GO (1.6 to 6.8 log,0 IU/ml) after automated extraction. The LOD of Gill virus was 10 IU/ml after manual extraction and between 25 and 37.5 IU/ml after automated extraction. Results with Gt2 and GO viruses were similar after automated extraction (Gt2, between 25 and 50 IU/ml; Gt3, 25 IU/ml). Variability (intrarun and interrun, at concentrations throughout the range of quantification) was less than or equal to13% for both extraction methods. Clinical specimens tested by Monitor were quantified using the CTM48 HCV ASR assay. Characteristics of the regression line included a slope of 0.98 and y intercept of -0.23. Quantification by the two methods was correlated (r = 0.97). CTM48 HCV ASR assay values were on average twofold lower than those for Monitor HCV v. 2.0. These data suggest that our assay combines the characteristics of qualitative and quantitative PCR platforms into a single test.
引用
收藏
页码:3581 / 3588
页数:8
相关论文
共 8 条
[1]   Hepatitis C virus subtyping by a core-envelope 1-based reverse transcriptase PCR assay with sequencing and its use in determining subtype distribution among Danish patients [J].
Corbet, S ;
Bukh, J ;
Heinsen, A ;
Fomsgaard, A .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (03) :1091-1100
[2]   Peginterferon alfa-2a plus ribavirin for chronic hepatitis C virus infection. [J].
Fried, MW ;
Shiffman, ML ;
Reddy, KR ;
Smith, C ;
Marinos, G ;
Goncales, FL ;
Haussinger, D ;
Diago, M ;
Carosi, G ;
Dhumeaux, D ;
Craxi, A ;
Lin, A ;
Hoffman, J ;
Yu, J .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (13) :975-982
[3]   Peginterferon-α2a and ribavirin combination therapy in chronic hepatitis C -: A randomized study of treatment duration and ribavirin dose [J].
Hadziyannis, SJ ;
Sette, H ;
Morgan, TR ;
Balan, V ;
Diago, M ;
Marcellin, P ;
Ramadori, G ;
Bodenheimer, H ;
Bernstein, D ;
Rizzetto, M ;
Zeuzem, S ;
Pockros, PJ ;
Lin, A ;
Ackrill, AM .
ANNALS OF INTERNAL MEDICINE, 2004, 140 (05) :346-355
[4]   Improved version 2.0 qualitative and quantitative AMPLICOR reverse transcription-PCR tests for hepatitis C virus RNA: Calibration to international units, enhanced genotype reactivity, and performance characteristics [J].
Lee, SC ;
Antony, A ;
Lee, N ;
Leibow, J ;
Yang, JQ ;
Soviero, S ;
Gutekunst, K ;
Rosenstraus, M .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (11) :4171-4179
[5]   Peginterferon alfa-2b plus ribavirin compared with interferon alfa-2b plus ribavirin for initial treatment of chronic hepatitis C: a randomised trial [J].
Manns, MP ;
McHutchison, JG ;
Gordon, SC ;
Rustgi, VK ;
Shiffman, M ;
Reindollar, R ;
Goodman, ZD ;
Koury, K ;
Ling, MH ;
Albrecht, JK .
LANCET, 2001, 358 (9286) :958-965
[6]   Genotype dependence of hepatitis C virus load measurement in commercially available quantitative assays [J].
Mellor, J ;
Hawkins, A ;
Simmonds, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (08) :2525-2532
[7]  
*NCCLS, 2003, MM6A NCCLS
[8]   Overestimation of the hepatitis C virus RNA content of reference preparations by the AMPLICOR HCV monitor test, version 2.0 [J].
Pisani, G ;
Cristiano, K ;
Wirz, M ;
Bisso, GM ;
Gentili, G .
JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (12) :4765-4767