Optical urea biosensor based on ammonium ion selective membrane

被引:14
作者
Chen, HM [1 ]
Wang, EJ [1 ]
机构
[1] St Johns Univ, Dept Chem, Jamaica, NY 11439 USA
关键词
optical urea biosensor; urease; anionic dye; ammonium neutral carrier; thin polymeric films;
D O I
10.1080/00032710008543104
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An optical urea biosensor was developed by immobilizing an urease enzyme layer on a thin ammonium-selective polymer membrane. The ammonium optical membrane utilized dichlorofluorescein octadecyl ester (DCFOE) as anionic chromophore and nonactin as neutral ionophore. The urease layer was coated on the top of the ammonium layer by gelatin entrapment combined with glutaradehyde cross-linking. Hydrolysis of urea catalyzed by urease produced ammonium ion, which was extracted into the polymer film to form complexes with nonactin. A proton was released which resulted in a color change of the optical membrane due to charge neutrality principle. The biosensorshowed response to urea in the range of 10(-5) to 0.1 M in 0.1 M Tris buffer at pH 7.4. The response time is 3-8 min. under non-stir conditions and it is completely reversible. The biosensor was found to be reliable in diluted serum samples for urea detection from 0.1 to 10 mM and good correlation was obtained with a potentiometric urea sensor.
引用
收藏
页码:997 / 1011
页数:15
相关论文
共 18 条
[1]   A COATED-METAL ENZYME ELECTRODE FOR UREA DETERMINATIONS [J].
ALEXANDER, PW ;
JOSEPH, JP .
ANALYTICA CHIMICA ACTA, 1981, 131 (NOV) :103-109
[2]   SELECTIVITY OF ION-SENSITIVE BULK OPTODES [J].
BAKKER, E ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1805-1812
[3]   A disposable biosensor for urea determination in blood based on an ammonium-sensitive transducer [J].
Eggenstein, C ;
Borchardt, M ;
Diekmann, C ;
Gründig, B ;
Dumschat, C ;
Cammann, K ;
Knoll, M ;
Spener, F .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (01) :33-41
[4]   SOLID-PHASE OPTOELECTRONIC SENSORS FOR BIOCHEMICAL-ANALYSIS [J].
GOLDFINCH, MJ ;
LOWE, CR .
ANALYTICAL BIOCHEMISTRY, 1984, 138 (02) :430-436
[5]  
JANATA J, 1992, ANAL CHEM, V64, P196
[6]   MICRO-OPTRODE FOR UREA USING AN AMMONIUM ION-SENSITIVE MEMBRANE COVERED WITH A UREASE-IMMOBILIZED MEMBRANE [J].
KAWABATA, Y ;
SUGAMOTO, H ;
IMASAKA, T .
ANALYTICA CHIMICA ACTA, 1993, 283 (02) :689-694
[7]   ENZYME BIOSENSOR FOR UREA BASED ON A NOVEL PH BULK OPTODE MEMBRANE [J].
KONCKI, R ;
MOHR, GJ ;
WOLFBEIS, OS .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (08) :653-659
[8]   AVIDIN BIOTIN COUPLING AS A GENERAL-METHOD FOR PREPARING ENZYME-BASED FIBER-OPTIC SENSORS [J].
LUO, SF ;
WALT, DR .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :1069-1072
[9]  
OSAKA T, 1996, SENSOR ACTUAT B-CHEM, V35, P463
[10]   FIBEROPTIC BIOSENSOR FOR UREA BASED ON SENSING OF AMMONIA GAS [J].
RHINES, TD ;
ARNOLD, MA .
ANALYTICA CHIMICA ACTA, 1989, 227 (02) :387-396